781453
23
Zoom out
Zoom in
Previous page
1/76
Next page
www.scheppach.com GB | 23
Places where the connection cables have been cut
due to being driven over.
Insulation damage due to being ripped out of the wall
outlet.
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables of the same designation.
The printing of the type designation on the connection
cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of C 16A or K 16A for machines with a high start-
ing current (from 3000 watts)!
11. Cleaning
m Attention!
Disconnect the mains plug before carrying out any
cleaning work.
We recommend that you clean the device directly after
every use.
Wipe swarf and dust o󰀨 the machine from time to time
with a cloth.
Clean the device at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic parts
of the device.
Make sure that no water can penetrate the device in-
terior.
12. Storage
Store the device and its accessories in a dark, dry
and frost-free place that is inaccessible to children.
The optimum storage temperature lies between 5
and 30 ˚C.
Store the power tool in its original packaging.
Cover the power tool to protect it from dust or mois-
ture.
Now t the intermediate part (13) using a total of four
llister head screws (17) (g. 5).
Place the housing cpl. with engine (3) on the ma-
chine stand and x it with a total of eight llister head
screws (17) (g. 6).
8.2 Fitting the dust bag (g. 7)
Attach the dust bag (10) to the lower air outlet using
the clamp tting (11) (g. 7).
8.3 Fitting the lter bag (g. 8)
Insert the retaining rod (1) into the housing cpl. with
engine (3) and hook in the lter bag (2) (g. 7).
8.4 Fitting the suction hose (g. 9 + 10)
Attach the suction hose (6) to the nozzle on the
housing cpl. with engine (3) and x it with a hose
clamp (14) (g. 9).
Attach the hose coupling (8) to the other end of the
hose (6) using a hose clamp (14) (g. 10).
9. Start up
m ATTENTION!
Always make sure the device is fully assembled
before commissioning!
9.1 Switching on/o󰀨, g. 1
To switch on, set the ON/OFF switch (4) to position
I”.
To switch the device o󰀨 again, set the ON/OFF
switch (4) to position “0”.
10. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The cus-
tomers mains connection as well as the exten-
sion cable used must also comply with these reg-
ulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
Pressure points, where connection cables are
passed through windows or doors.
Kinks where the connection cable has been improp-
erly fastened or routed.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach DC500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach DC500 in the language / languages: English, German, Danish, Swedish, Finnish as an attachment in your email.

The manual is 3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info