The compressor may only be used in suitable
rooms (with good ventilation and an ambient tem-
perature from +5 °C to 40 °C). There must be no
dust, acids, vapors, explosive gases or inamma-
ble gases in the room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor in
areas where work is conducted with sprayed water.
8. Attachment and operation
m Important!
You must fully assemble the appliance before
using it for the rst time!
Mains connection
The compressor can be connected to any 220 -
240-240 V~ 50 Hz shock-proof socket which is pro-
tected by a 16 A fuse.
Before you use the machine, make sure that the
mains voltage is the same as the operating voltage
(see the rating plate).
Long supply cables, extensions, cable reels etc.
cause a drop in voltage and can impede motor
start-up.
At low temperatures below +5°C, sluggishness
may make starting difcult or impossible.
ON/OFF switch (g. 1)
To switch on the compressor, press the button (2)
on position I.
To switch off the compressor, press the button (2)
on position 0.
Establishing connections (g. 3, 4)
m Attention! Switch the device off for this.
When doing so, hold the coupling rmly in order to
avoid injuries due to the hose springing back.
Connect the tting of your compressed air tool to
the compressed air hose (5) of the compressor.
To disconnect this coupling again, pull the quick-
coupling (4) back at the compressed air hose (5).
Using the tyre ination device (g. 6, 7, 8)
The compressed air tyre ination device (G) is used
to inate car tyres. With the corresponding accesso-
ries it can also be used to inate and regulate bicycle
tyres, inatable dinghies, air mattresses, balls etc.
Pressure can be released by actuating the vent valve
(7).
m Attention! The manometer has not been ofcially
calibrated! After inating, please check the air pres-
sure with a calibrated device.
Using an air blow gun
You can also use the tyre ination device (G) as an
air blow gun to clean out cavities and to clean soiled
surfaces and work equipment.
6. Technical data
Mains connection 220 - 240 V~ 50 Hz
Motor rating max. 1100 W
Operating mode S3 15%
Compressor speed 3750 min-1
Operating pressure approx. 8 bar
Theoretical intake
capacity approx. 180 (l/min)
Sound power level LWA 97 dB(A)
Uncertainty KWA 1.93 dB
Protection type IP20
Protection class II
Weight of the unit 5.5 kg
The noise emission values were measured in ac-
cordance with EN ISO 3744.
Wear hearing protection.
The effects of noise can cause a loss of hearing.
Residual risks
Comply with the stipulated maintenance and safety
instructions in the operating instructions.
Remain attentive at all times when working and keep
third parties at a safe distance from your work area.
Even when the device is being used properly, there
will always be certain residual hazards that cannot
be completely ruled out. The following potential haz-
ards can arise due to the type and design of the
device:
Unintentional starting up of the product.
Damage to hearing if the stipulated hearing pro-
tection is not worn.
Dirt particles, dust etc. can get into the eyes or
face despite wearing safety goggles.
Inhaling swirled up particles.
7. Before starting the equipment
Before you connect the equipment to the mains sup-
ply make sure that the data on the rating plate are
identical to the mains data.
Check the equipment for damage which may have
occurred in transit. Report any damage immedi-
ately to the transport company which was used to
deliver the compressor.
Install the compressor near the point of consump-
tion.
Avoid long air lines and supply lines (extension
cables).
Make sure that the intake air is dry and dustfree.
Do not install the compressor in a damp or wet
room.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach Air Force at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach Air Force in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 10.02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info