BOILER LOCATION
Clearances
The position of the boiler must be such that there is
adequate space for servicing.
The recommended clearances are:
40 mm either side of the boiler.
600 mm at the front of the boiler.
300 mm below the boiler.
300 mm above the boiler.
Fixing jig
The fixing jig comprises three parts:
1) The connecting plate which allows the connec-
tion and soundness testing of all the pipework be-
fore the boiler is fitted and helps support the weight
of the boiler.
2) The hook which supports the weight of the boiler.
3) The template which ensures the hook and con-
necting plate are correctly fitted relative to one
another.
Place template on wall in required position, mak-
ing allowances for the necessary clearances etc.
Note: It is permissible to install the boiler with re-
duced clearances at the bottom and sides of the
boiler PROVIDING that adequate consideration is
given for Servicing/Repairs at a later date. If any
doubt exists, contact the Saunier Duval Technical
Helpline 01773 828400.
Mark the position of the holes for the hook and
connecting plate.
Drill, plug and fix the connecting plate and hook
to the wall using suitable screws.
Check that both the hook and connecting plate
are level.
If the boiler is not installed immediately, protect the
various couplings to prevent any ingress of foreign
materials e.g. plaster, paint etc.
Terminal position
The minimum acceptable spacings from the ter-
minal to obstructions and ventilation openings are
shown in diagram 8.
The boiler must be installed so that the terminal is
exposed to the external air.
Should any doubt exist as to the permissible posi-
tion of the terminal, contact the Saunier Duval
Technical Helpline 01773 828400.
Cupboard or compartment ventilation
The boiler can be fitted in a cupboard or compart-
ment as long as adequate permanent high and
low level ventilation is provided in accordance with
ventilation requirements
Ven 060a
N
C
D
M
A
B
E
F
G
I
H
L
Minimum dimensions (in mm) for the positioning of flue terminals
A-under a window ............................................ 300
B-under an air vent .......................................... 300
C-under a gutter ................................................. 75
D-under a balcony ........................................... 300
E-from an adjacent window........................... 300
F-from an adjacent air vent ........................... 300
G-from vertical or horizontal air pipes ............... 300
H-from an external corner of the building ..... 300
I-from an internal corner of the building ...... 300
L-from the ground or from another floor ........... 300
M-between two terminals vertically ............ 1500
N-between two terminals horizontally ........... 600
Ins 005a
Diagram 7
135135
767
889
5963
520
Diagram 8
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Saunier Duval Thelia 30 e at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Saunier Duval Thelia 30 e in the language / languages: English as an attachment in your email.

The manual is 0,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info