BOILER CONNECTIONS
From left to right the fixing jig comprises :
A-Heating return with isolating valve (m).
B-Cold water inlet with isolating valve (p).
C-Heating flow with isolating valve (q), drain
screw (r) and safety valve (s).
D-Domestic hot water outlet.
E-Electrical connection box.
F-Gas supply.
Diagram 5
Filters and washers:
1 - Fibre washer
2 - Metal filter
3 - Plastic filter
4, 5 and 6 -Black graphite
PIPING SYSTEM INSTALLATION
Heating system connections - Pipe diam 22 mm
Hot water system connections - Pipe diam 15 mm
Gas connection - Pipe diam 22 mm
Safety valve discharge - Pipe diam 15 mm
Water connection
Connect the copper tails and isolating cocks sup-
plied, to the boiler, see diagram 5. Connect the
system pipework to the boiler observing the cor-
rect flow and return format as shown in diagram 5.
Safety valve discharge
WARNING. It must not discharge above an en-
trance or window or any type of public access
area.
Connect the safety valve discharge pipe to the
boiler, the discharge must be extended using not
less than 15 m o.d. pipe, to discharge in a visible
position outside the building, facing downward
preferably over a drain. The pipe must have a con-
tinuous fall and be routed to a position so that any
discharge of water, possibly boiling or steam, can-
not create any danger to persons, damage to
property or external electrical components and
wiring. Tighten all pipe connection joints.
Connect the safety valve discharge pipe to the
boiler, the discharge must be extended using not
less than 15 m o.d. pipe, to discharge in a visible
position outside the building, facing downward
preferably over a drain. The pipe must have a con-
tinuous fall and be routed to a position so that any
discharge of water, possibly boiling or steam, can-
not create any danger to persons, damage to
property or external electrical components and
wiring. Tighten all pipe connection joints.
Gas connection
The supply from the governed gas meter must
be of adequate size to provide a constant inlet
working pressure of 20 mbar (8 in w.g.).
To avoid low gas pressure problems, it is recom-
mended that the gas supply is connected using 22
mm pipe.
On completion, the gas installation must be
tested using the pressure drop method and purged
in accordance with the current issue of BS6891.
Gas Safety (Installation and Use) Regulations
In your interests and that of gas safety, it is the law
that ALL gas appliances are installed and serviced
by a competent person in accordance with the
above regulations.
1
2
3
4
5
6
55
55
57,5
57,5
r
p
q
34
25
23
113
s
33
A
B
C
D
F
E
m
Pla 041
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Saunier Duval Thelia 30 e at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Saunier Duval Thelia 30 e in the language / languages: English as an attachment in your email.

The manual is 0,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info