36 VERSA Plus SATEL
4.4 Arming
Prevent arming if not ready – when the option is enabled, if the user arm the system by
means of keypad or keyfob, the control panel checks that there are no circumstances that
prevent the arming:
a zone with PRIORITY option is violated in the partition which is to be armed,
– the 3. INSTANT, 4. DOUBLE KNOCK, 5. 24H BURGLARY, 6. 24H TAMPER, 7. 24H PANIC, 8. 24H
PANIC SILENT
, 9. 24H MEDICAL or 10. 24H FIRE type zone is violated in the partition which
is to be armed,
there is a trouble in the system.
If one of the aforementioned situations takes place, the control panel will not start the
arming procedure (the LCD keypad enables forced arming – see: USER MANUAL). If none of
the conditions is met, the control panel will start the arming procedure, but at the end of
the exit delay countdown it will check again if the arming is possible (the quick arming
being an exception). A violated zone or a trouble mean that the arming is not possible (i.e.
the arming procedure will fail).
Additionally, when the option is enabled and the user has the INSPECTION right, the LCD
keypad will inform, prior to arming, that there are bypassed zones in the partition (it does
not apply to the quick arming).
You can enable/disable the option in keypad: SERVICE MODE 2. HARDWARE 1. KPDS &
EXPS
. 4. OPTIONS ADVANCED ARMING.
Arm even if not ready after exit delay – if the option is enabled, a zone violation or trouble
found at the end of exit delay countdown does not affect the arming procedure – the
system will be armed. You can enable/disable the option in keypad: SERVICE MODE
2. HARDWARE 1. KPDS & EXPS. 4. OPTIONS ARM EXDLY W.TRBL. The option is
available, when the PREVENT ARMING IF NOT READY or GRADE 2 option is enabled.
4.5 Other global parameters
Rings before answer – number of rings after which the control panel will answer the
incoming call. The parameter refers to the analog communicator. In the keypad, you can
program this parameter: SERVICE MODE 7. ANSWERING 1. RINGS TO ANS.
User code min. lenght – the minimum number of characters required for the control panel to
accept a new code or a changed code. This parameter will be included when creating and
editing the codes (it is irrelevant to the codes already existing in the system).
5. Partitions
The partition is a separated area within the premises protected by the security alarm system.
The subdivision into partitions enables arming/disarming the system only in part of the
protected area, as well as limiting access to some portion of the premises to selected users.
You can create 2 partitions.
5.1 Configuring the partitions
You can configure the partitions as follows:
DLOADX program: “VERSA – Structure” window “System” tab. Partitions and zones are
presented in the form of tree structure on the left side of the window (Fig. 6). Click on the
partition you want to configure.
keypad: functions available in the PARTITIONS submenu (SERVICE MODE 1. PARTITIONS).
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Versa Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Versa Plus in the language / languages: English as an attachment in your email.

The manual is 2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Versa Plus

Satel Versa Plus User Manual - English - 44 pages

Satel Versa Plus Installation Guide - English - 36 pages

Satel Versa Plus Quick start guide - English - 11 pages

Satel Versa Plus Installation Guide - English - 32 pages

Satel Versa Plus Quick start guide - German - 12 pages

Satel Versa Plus Additional guide - German - 113 pages

Satel Versa Plus User Manual - German - 46 pages

Satel Versa Plus Installation Guide - German - 36 pages

Satel Versa Plus Quick start guide - Dutch - 11 pages

Satel Versa Plus User Manual - Dutch - 46 pages

Satel Versa Plus Additional guide - Dutch - 110 pages

Satel Versa Plus Additional guide - Dutch - 2 pages

Satel Versa Plus Installation Guide - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info