ASD-150 detector
1. Enter a number from the 0 to 50 range to define the rules of device presence control, and
then press .
2. Press any numeric key to define whether the detector is to signal alarm from other
ASD-150 detectors ( – no, – yes), and then press .
3. Press any numeric key to define whether the detector is to send out alarm to other
ASD-150 detectors ( – no, – yes), and then press .
AVD-100 detector
Having selected the first of the zones to which the detector is assigned:
1. Enter a number from the 0 to 50 range to define the rules of device presence control, and
then press .
2. Press any numeric key to define whether the detector is to be always active ( – no,
yes), and then press .
3. Use the and keys to select which of the two reed switches (bottom or side) of
the magnetic contact is to be active, and then press .
Having selected the second of the zones to which the detector is assigned:
1. Enter a digit from the 1 to 8 range to define sensitivity of the vibration detector (1 –
minimum; 8 – maximum), and then press .
2. Enter a digit from the 0 to 7 range to define the number of pulses that will trigger alarm,
and then press .
ASP-100 siren
1. Enter 0, if presence of the siren is not to be checked, or enter a number from the 1 to 50
range, if presence of the siren is to be checked (the number entered is irrelevant – if there
is no communication during a 1-hour period, absence of the device will be reported), and
then press .
2. Use the and keys to select the type of acoustic signaling, and then press
.
3. Use the
and keys to define the maximum duration of signaling, and then
press .
ASP-105 siren
4. Enter a number from the 0 to 50 range to define the rules of device presence control, and
then press .
5. Use the and keys to select the type of acoustic signaling, and then press
.
6. Use the and keys to define the maximum duration of acoustic signaling, and
then press .
ASP-205 siren
For the ASP-205 siren, you can program two different ways of signaling:
having selected the first of the zones to which the siren is assigned: signaling triggered by
the first output controlling the siren,
having selected the second of the zones to which the siren is assigned: signaling triggered
by the second output controlling the siren.
Configuration is similar for both zones, however, the step in which the rules of device
presence control are defined is skipped for the second zone.
63


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Versa IP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Versa IP in the language / languages: English as an attachment in your email.

The manual is 1,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Versa IP

Satel Versa IP Quick start guide - English - 11 pages

Satel Versa IP User Manual - English - 32 pages

Satel Versa IP Installation Guide - English - 36 pages

Satel Versa IP User Manual - English - 43 pages

Satel Versa IP Quick start guide - German - 11 pages

Satel Versa IP Additional guide - German - 97 pages

Satel Versa IP User Manual - German - 45 pages

Satel Versa IP Installation Guide - German - 38 pages

Satel Versa IP Quick start guide - Dutch - 2 pages

Satel Versa IP User Manual - Dutch - 45 pages

Satel Versa IP Quick start guide - Dutch - 12 pages

Satel Versa IP Additional guide - Dutch - 93 pages

Satel Versa IP User Manual - Dutch - 45 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info