SATEL PERFECTA LTE 25
generated. Alarms from the 0. E
NTRY
/E
XIT
, 1. E
NTRY
/E
XIT FINAL
, 2. I
NTERNAL
, 3. I
NSTANT
,
4. D
OUBLE KNOCK
or 5. 24
H
B
URGLARY
zones are verified. The time is counted from the
moment of alarm triggering by this type of zone.
Exit delay clearing enable [Fin.exit delay] – if this option is enabled, the users can terminate
the exit delay countdown by using keypad (the , or key is to be pressed
and hold down for about 3 seconds).
Infinite exit delay [Infinit.ex.delay] – if this option is enabled, the exit delay time is infinite. It
can be terminated:
on violation of the 1. E
NTRY
/E
XIT FINAL
, 16. E
XIT
D
ELAY
T
ERMINATOR
or 17. S
HUNT
L
OCK
type zones,
after pressing and holding down for 3 seconds the , or keys on the
keypad (when the E
XIT DELAY CLEARING ENABLE
option is enabled).
If the exit delay countdown is not terminated, the partition will not be armed.
Entry delay in Night Arm [Entry del. night] – if this option is enabled, there is entry delay
when the partition is armed in night mode. If this option is disabled, there is no entry delay
when the partition is armed in night mode.
Entry delay in Day Arm [Entry del. day] – if this option is enabled, there is entry delay when
the partition is armed in day mode. If this option is disabled, there is no entry delay when
the partition is armed in day mode.
6. Zones
A zone can be assigned to one or two partitions. If the zone is assigned to two partitions, it
can be armed when both partitions are armed or one of them only.
The system supports the following zones:
hardwired – on the control panel PCB and in expanders. The number of available
hardwired zones is determined by the control panel during the identification procedure.
wireless – in the PERFECTA 32-WRL LTE control panel, after adding wireless detectors.
The number of available wireless zones depends on the number of wireless detectors
registered in the system.
virtual – zones which do not physically exist, but are controlled by means of keyfobs.
6.1 Zone parameters and options
Name [38.Names] – individual name of zone (up to 16 characters).
Wiring type [31.EOL] – type of detector and the method of its connection:
No detector – no detector is connected to the zone,
NC – the zone supports a detector of NC (normally closed) type,
NO – the zone supports a detector of NO (normally open) type,
EOL – the zone supports a detector of NO or NC type with EOL resistor in the circuit,
2EOL/NO – the zone supports a detector of NO type with two EOL resistors in the circuit,
2EOL/NC – the zone supports a detector of NC type with two EOL resistors in the circuit,
Roller – the zone supports a roller shutter detector,
Vibration – the zone supports a vibration detector (also NC type detector).
Opening the V
IBRATION
circuit for 200 ms or longer – irrespective of the programmed
number of pulses and sensitivity (see below) – will result in a zone violation. This
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel PERFECTA 32 LTE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel PERFECTA 32 LTE in the language / languages: English as an attachment in your email.

The manual is 0,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel PERFECTA 32 LTE

Satel PERFECTA 32 LTE Quick start guide - English - 10 pages

Satel PERFECTA 32 LTE User Manual - English - 30 pages

Satel PERFECTA 32 LTE Additional guide - English - 50 pages

Satel PERFECTA 32 LTE Installation Guide - English - 26 pages

Satel PERFECTA 32 LTE User Manual - German - 11 pages

Satel PERFECTA 32 LTE Additional guide - German - 50 pages

Satel PERFECTA 32 LTE Installation Guide - German - 27 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info