699537
26
Zoom out
Zoom in
Previous page
1/47
Next page
24 PERFECTA LTE SATEL
information about short-time voltage decays, having no effect on normal operation of the
system. The parameter is valid for the module with power supply.
5. Partitions
Fig. 14. “Partitions” tab.
The partition is a separated area within the premises protected by the security alarm system.
The subdivision into partitions enables arming/disarming the system only in part of the
protected area, as well as limiting access to some portion of the premises to selected users.
You can create 2 partitions.
5.1 Partition parameters
Part. name [18.Names] – individual name of the partition (up to 16 characters).
Exit delay [13. Exit delay] – time counted from the moment of starting the procedure of
partition arming. It allows the user to leave the protected area without triggering alarm. You
can enter from 0 to 255 seconds. Entering zero 0 means no exit delay time.
The exit delay countdown can be terminated by using keypad (see E
XIT DELAY
CLEARING ENABLE
option) or zones of the 1. E
NTRY
/E
XIT FINAL
, 16. E
XIT
D
ELAY
T
ERMINATOR
or 17. S
HUNT
L
OCK
type.
Warning time [14.Warn.delay] – duration of the warning alarm. You can enter from 0 to 255
seconds. Entering any value different from 0 means enabling the warning alarm feature.
The alarm alerts the user that he or she has forgotten to disarm the partition or made
mistakes when arming the partition. The warning alarm is triggered when:
– E
NTRY DELAY
time has elapsed (see: p. 27),
DELAY
time has elapsed (see: p. 27),
– 3. I
NSTANT
or 4. D
OUBLE KNOCK
zone triggered alarm when E
NTRY DELAY
countdown was
running,
– 0. E
NTRY
/E
XIT
, 1. E
NTRY
/E
XIT FINAL
or 2. I
NTERNAL
type zone is violated at the moment
when the exit delay countdown expires and the partition is armed (see description of
P
REVENT ARMING IF NOT READY
p. 15 and P
RIORITY
options p. 27).
The warning alarm can be signaled by keypad or 2. I
NTERNAL SIREN
type output. It is not
reported. If the partition is not disarmed during the warning alarm, the burglary alarm will
be triggered.
Alarm verif. time [15.Verif.delay] – time for verification of the alarm. You can enter from 0 to
255 minutes. Entering any value different from 0 means activation of the burglary alarm
verification function. The verification consists in checking whether another zone will trigger
the burglary alarm within the defined period of time. If so, the verified alarm will be
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel PERFECTA 32 LTE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel PERFECTA 32 LTE in the language / languages: English as an attachment in your email.

The manual is 0,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel PERFECTA 32 LTE

Satel PERFECTA 32 LTE Quick start guide - English - 10 pages

Satel PERFECTA 32 LTE User Manual - English - 30 pages

Satel PERFECTA 32 LTE Additional guide - English - 50 pages

Satel PERFECTA 32 LTE Installation Guide - English - 26 pages

Satel PERFECTA 32 LTE User Manual - German - 11 pages

Satel PERFECTA 32 LTE Additional guide - German - 50 pages

Satel PERFECTA 32 LTE Installation Guide - German - 27 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info