23. ARM/DISARM BEEPsignals:
starting the arming procedure (arming, if the exit delay has not been programmed)
1 tone,
disarming 2 tones,
clearing alarm 4 tones,
denial of arming or arming procedure failure 7 tones.
The tone duration is approx. 0.3 seconds.
24. MONO SWITCH controlled by users, zones or timers. Using a code, zone violation or
turning timer on will activate the output for a preprogrammed time.
25. BI SWITCH controlled by users, zones or timers. Depending on the current status, using
a code or violating a zone will activate/deactivate the output. Turning the timer ON
activates the output, and turning the timer OFF deactivates the output.
If the 24. MONO SWITCH or 25. BI SWITCH type output is to be controlled from the
keypad, it must be assigned to a group of outputs (see: “Output groups p. 68).
26. TIMERthe output controlled by timers.
27. TROUBLE STATUSindicates the troubles.
28. AC LOSS (MAINBOARD) IMMEDIATE indicates the loss of AC power to the control panel
mainboard.
29. AC LOSS (TECHNICAL ZONE) indicates the violations of 59. TECHNICAL-AC LOSS type
zones.
30. AC LOSS (EXPANSION MODULE) indicates the loss of AC power to the modules with power
supply.
31. BATTERY TROUBLE (MAINBOARD) indicates the low battery of the control panel mainboard.
32. BATTERY TROUBLE (TECHNICAL ZONE) indicates the violations of 60. TECHNICAL-BATTERY
LOW
type zones.
33. BATTERY TROUBLE (EXPANSION MODULE) indicates the low battery of the modules with
power supply.
34. DETECTOR TROUBLE indicates the zone troubles.
35. TELEPHONE LINE IN USE STATUS indicates that the telephone communication is in use.
36. GROUND STARTgenerates a control pulse necessary for work with some types of
telephone exchange.
37. REPORTING ACKNOWLEDGEMENTindicates the acknowledgement of reporting.
38. SERVICE MODE STATUSindicates that the service mode is entered.
39. TEST VIBRATION DETECTORS intended for testing the vibration detectors in one partition
(see: 10. 24H VIBRATION zone type). The output cut-off time defines the duration of testing
the vibration detectors in the selected partition.
40. CASH MACHINE BYPASS STATUS indicates bypassing the 11. 24H CASH MACHINE type
zones in partitions with cash dispenser.
41. POWER SUPPLY intended for supplying external devices.
42. POWER SUPPLY ON ARMED dedicated to powering the detectors which should not be
active when the system is disarmed. Gets active when the arming procedure is started
(active during the exit delay countdown).
43. RESETABLE POWER SUPPLY the power supply output with optional reset by the user. The
programmed cut-off time is the time during which the output will be turned off.
44. FIRE DETECTORS POWER SUPPLY intended for supplying the fire detectors with automatic
alarm verification. Violating the fire zone will turn the power off (for the time programmed
65


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 64 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 64 in the language / languages: English as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 64

Satel Integra 64 User Manual - English - 51 pages

Satel Integra 64 Installation Guide - English - 36 pages

Satel Integra 64 Additional guide - German - 121 pages

Satel Integra 64 User Manual - German - 54 pages

Satel Integra 64 Installation Guide - German - 38 pages

Satel Integra 64 Quick start guide - German - 2 pages

Satel Integra 64 User Manual - Dutch - 52 pages

Satel Integra 64 Quick start guide - Dutch - 24 pages

Satel Integra 64 Additional guide - Dutch - 121 pages

Satel Integra 64 Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info