2. FIRE/BURGLARY signals the burglary and panic alarms (continuous sound) and the fire
alarms (intermittent sound).
3. FIRE ALARM signals the fire alarms (from fire zones and triggered from keypads).
4. KEYPAD ALARM signals the alarms triggered from keypad: fire, medical (auxiliary) and
panic (except: silent panic alarm).
5. FIRE (FROM KEYPAD) signals the fire alarms triggered from keypad.
6. PANIC (FROM KEYPAD) signals the loud panic alarms triggered from keypad.
7. MEDICAL ALARM (FROM KEYPAD) signals the medical assistance call alarm triggered from
keypad.
8. TAMPER ALARM signals the tamper alarms.
9. DAY ALARM signals the following:
alarms from 13. PANIC-SILENT type zones,
medical alarms from the 14. MEDICAL - BUTTON and 15. PERSONAL EMERGENCY type
zones,
alarms from 7. DAY/NIGHT type zones, if the partition to which the zone belongs is
disarmed,
alarms from 8. EXTERIOR type zones, if the armed mode which assumes that the user
will stay inside the protected facility is enabled in the partition (see: USER MANUAL),
alarms from 4. PERIMETER type zones, if the SIGNALING DELAY has been programmed for
them,
alarm from 5. INSTANT and 6. EXIT type zones, if the BELL DELAY option has been
enabled and the SIGNALING DELAY has been programmed for them,
alarms from zones, for which the REPORTING DELAY option has been enabled, provided
they were violated during the ENTRY DELAY countdown,
unverified alarms, if the AUDIBLE ALARM AFTER VERIFICATION option is enabled for the
partition,
the first violation of the 8. EXTERIOR type zones when they are armed, provided the
SURVEILLANCE TIME has been programmed for the zone,
violation of the counting zones (16-31 type zones) when armed.
10. DURESS ALARM action carried out under duress signals that a DURESS type code
(or prefix) has been used in the system.
11. CHIME signals violation of the zones when they are disarmed.
12. SILENT ALARMactivates in the same situations as the 9. DAY ALARM output. Additionally,
it can signal silent panic alarms.
13. TECHNICAL ALARMsignals alarms from zone types 40-56.
14. ZONE VIOLATIONindicates the violations of zones.
15. VIDEO ON DISARMEDcontrolled by zones with the VIDEO ON DISARMED option enabled.
16. VIDEO ON ARMEDcontrolled by zones with the VIDEO ON ARMED option enabled.
17. READY STATUS indicates whether the system is ready for arming, i.e. whether there are
no violated zones (active when there is no violation).
18. BYPASS STATUSindicates the bypassing of zones.
19. EXIT DELAY STATUS indicates the EXIT DELAY countdown.
20. ENTRY DELAY STATUSindicates the ENTRY DELAY countdown.
21. ARMED STATUS indicates the armed status of partitions.
22. FULL ARMED STATUSactive if all selected partitions are armed.
64


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 64 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 64 in the language / languages: English as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 64

Satel Integra 64 User Manual - English - 51 pages

Satel Integra 64 Installation Guide - English - 36 pages

Satel Integra 64 Additional guide - German - 121 pages

Satel Integra 64 User Manual - German - 54 pages

Satel Integra 64 Installation Guide - German - 38 pages

Satel Integra 64 Quick start guide - German - 2 pages

Satel Integra 64 User Manual - Dutch - 52 pages

Satel Integra 64 Quick start guide - Dutch - 24 pages

Satel Integra 64 Additional guide - Dutch - 121 pages

Satel Integra 64 Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info