699578
21
Zoom out
Zoom in
Previous page
1/36
Next page
CA-6 SATEL 19
Note: The OUT1, OUT2, and OUT3 outputs must be loaded with resistors installed in the
sirens. It is necessary for correct operation of the system and for load presence check.
We recommend using 2.2 kresistors. If the acoustic siren, connected to one of the
outputs, produces some undesirable low sounds in deactivated state, the resistor
should be decreased.
COM
OUT5
OUT4
+
12V
OUT4
OUT5
COM
+12V
-
+
+Ucc
+12V
R
OUT n
P
12V
OUT n
Fig. 11. Diagram of OUT4, OUT5 low-current outputs and load connection.
The OUT4 and OUT5 outputs can be used to control the relays switching on any sirens or
other equipment. The relays may be directly connected to the outputs, as shown in Figure 11.
The OUT4 and OUT5 outputs can also be used to control the NOKTON NR2-DSC radio
monitoring transmitter (NEMROD system format PC16OUT). In such a case it is necessary
to change the operating mode of these outputs by activating a suitable option in the service
function 5. During operation with the NOKTON transmitter, the outputs are used for
transmitting a number of data on the control panel state (zone alarms, fire alarms, troubles,
armed mode, etc.) and do not perform functions programmed with the standard service
functions.
(PGM)
(TAKT)
8
15
14
13
12
9
1
2
DB-15
COM
OUT5
OUT4
+
12V
Fig. 12. Connection of NR2-DSC transmitter, made by NOKTON.
When hooking up to the control panel any equipment with a considerable
current consumption (e.g. a radio monitoring transmitter), their "+" should be
connected to the battery "+" (a fuse is required on the feeder cable). The ground
must be connected to any COM terminal of the control panel, but not directly to
CA-6
low-current output
connector
NR2-DSC transmitter socket
fuse
250 V/2 A
to battery „+”
to mainboard AC terminal
to COM terminal (next to OU1 terminal)
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel CA-6 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel CA-6 in the language / languages: English as an attachment in your email.

The manual is 0,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel CA-6

Satel CA-6 Additional guide - English - 40 pages

Satel CA-6 Quick start guide - English - 8 pages

Satel CA-6 Additional guide - German - 19 pages

Satel CA-6 User Manual - German - 19 pages

Satel CA-6 Installation Guide - German - 80 pages

Satel CA-6 User Manual - German - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info