4.6.2 Silent armed mode
The supervision mode during which the alarms are transmitted to the monitoring station,
signaled in the keypad, and on the K
EYPAD ALARM
type of output.
4.6.3 Partial armed mode with no exit from the site
The armed mode with automatic bypassing of the zones (detectors) assigned by the
installer. If, after arming the system, the user has not left the site and has not violated
the entry/exit monitoring line during the exit delay, the selected zones of the control
panel will be automatically bypassed, and activation of the detectors connected to those
zones will trigger no alarm.
4.7 A
RMING
[CODE][#]
The arming is only possible when the system is signaling no alarm and it is not in the armed
mode: the [ALARM] and [ARMED] LEDs are off.
In order to arm the system, enter the user access code and confirm it with the [#] key. If you
made a mistake when entering the access code, press the [
*
] key and re-enter the code. The
access codes should be entered very carefully. Three consecutive mistakes may trigger the
alarm recorded in the events log as the „3 wrong codes alarm”.
If the code is entered correctly and arming is possible, the control panel will confirm the entry
with four short beeps followed by a long one and will get armed. In case the installer has pre-
programmed the „exit delay”, the [ARMED] LED will start blinking to indicate beginning of
that time countdown, and arming will take place when the countdown is over. The LCD
keypad will display information about exit time delay.
The installer determines the length of the exit delay and the way the audible signaling works.
EXAMPLE: Arming with the user access code: 39763.
press in turn: [3][9][7][6][3] [#]
The control panel may fail to arm the system if:
the panel is not ready for arming the system: there are zones defined by the installer
which must not be violated or tampered while the system is being armed („
PRIORITY
option) and one of them is being violated or tampered – the panel signals this state with
three long beeps and displays the names of violated zones on LCD keypad.
In such a situation, you should wait until all the zones are ready (in the LED keypad the
LEDs 1÷5 will go out; in the LCD keypad – symbols of zone violation) and then arm the
system again (enter the access code). If, for example, one of the zones remains all the
time violated (in the LED keypad one of the LEDs 1÷5 is always on, in the LCD keypad the
symbol of zone violation is displayed – it may be caused e.g. by the detector failure), the
armed mode can be activated after bypassing the given zone (using the function 4);
the access code is incorrect – this situation is signaled with two long beeps.
at least one output in the system performs the D
URESS ALARM
function and is on (active).
Using the code which does not carry out the „action under duress” function will reset the
a.m. output activity (three short beeps) without arming the system; the system will only be
armed on using any code again.
4.8 Q
UICK ARMING
[0][#]
Quick arming without using any access code is possible by consecutive pressing of two
keypad keys:
EXAMPLE: [0][#] – arming
The control panel cannot arm the system when:
an alarm condition is signaled by the panel (the [ALARM] LED is blinking);
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel CA-5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel CA-5 in the language / languages: English as an attachment in your email.

The manual is 0,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel CA-5

Satel CA-5 Additional guide - English - 20 pages

Satel CA-5 Quick start guide - English - 12 pages

Satel CA-5 Installation Guide - English - 27 pages

Satel CA-5 Additional guide - German - 20 pages

Satel CA-5 User Manual - German - 24 pages

Satel CA-5 Installation Guide - German - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info