10
It is recommended that the cable be connected first to the control panel connector, and
then to the computer connector.
3. The JP1 RESET” pins – make it possible to start the service mode without entering any
service code. This function can be disabled by the installer with the software means (see:
FS 9 – Option 1).
4. The DIALER” LED – it is lit up during telephone messaging by the control panel, and
blinks during pulse dialing.
Next to the LED is situated an adjustable resistor. Its setting should not be
changed, since it would cause incorrect work of the dialer (loss of the capability
of dialing in the DTMF system and monitoring in the „Ademco Ex” and „Contact
ID” formats).
BOARD TERMINALS:
AC module power supply inputs (18 V AC ± 10%)
Z1 to Z5zones
OUT1 signaling output (current-carrying capacity 1.1 A)
OUT2, OUT3 control panel programmable outputs (current-carrying capacity 50 mA)
DATA, CLK keypad bus terminals
KPD keypad power supply output (+12 V)
AUX detectors power supply output (+12 V)
COM common (0 V)
protective terminal – ground (connect to protective circuit only)
TIP, RING external telephone line terminals
T-1, R-1 internal telephone line terminals (telephone set connection)
The AC terminals are intended for the supply of alternating voltage from the mains
transformer. The control panel power supply is suitable for operation with the input voltage of
18 V AC ± 10%. The control panel is fitted with an advanced pulse-type power supply of high
energy efficiency and operational reliability, the correct functioning of which requires,
however, that the input voltage at the maximum load of the transformer by the control panel
never drop below 16 V AC.
The control panel power supply (current efficiency 1.2 A) is fitted with:
voltage stabilization system (the voltage value of 13.6 V–13.8 V DC is factory set during
production process and should not be changed);
battery status monitoring system with optional disconnection of the battery if discharged
- during testing the processor reduces the power supply voltage to about 10.5 V and the
consumers are powered from the battery. The testing takes place every 4 minutes and
lasts for less than twenty seconds. If the battery voltage drops down to about 11 V, the
control panel will report a trouble. In case of the voltage fall to 9.5 V, the control panel will
cut off the battery in order to prevent it from being completely discharged and damaged.
Attention should be paid so as not to cause overloading of the control panel power supply in
the security system. It is advisable to make a load balance for the power supply. The total
current inputs for the consumers (detectors, keypads) and the battery charging current may
not exceed the power supply capacity. In case of a higher electric power demand, an
additional power supply can be used for some of the security system consumers
(e.g.: APS-15, APS-30 manufactured by SATEL). Table 1 (at the end of this manual) shows
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel CA-5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel CA-5 in the language / languages: English as an attachment in your email.

The manual is 0,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel CA-5

Satel CA-5 Additional guide - English - 20 pages

Satel CA-5 User Manual - English - 24 pages

Satel CA-5 Quick start guide - English - 12 pages

Satel CA-5 Additional guide - German - 20 pages

Satel CA-5 User Manual - German - 24 pages

Satel CA-5 Installation Guide - German - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info