CA-10 Installer Manual 33
Note: The names contained in the data of the first partition LCD keypad are used as
descriptions when scrolling through the event log.
In order to program the data you should:
connect the RS-232 ports of keypad and computer with a corresponding cable (see:
DESCRIPTION OF CONTROL PANEL MAIN BOARD, point number 3 – RJ socket),
Note: For programming the LCD keypad a different cable is necessary than for
programming main board via RS-232 port. The cable for programming the LCD
keypad is available in the kit designated DB9F/RJ-KPL.
start the DLOAD10 program in the computer and select the COM port to which the cable
is connected (see: Program configuration for...),
open the file with alarm system data,
open the LCD keypads window and select the corresponding keypad (tabs:
LCD 1...LCD 4),
start the data readout by clicking on the Read field on the right-hand side of open window
(the correct readout operation is confirmed by the status bar indicator at the bottom of the
window),
enter the data in the corresponding fields of the computer screen,
save the data in the keypad memory by clicking on the Write field just below the Read
field,
disconnect the cable from the keypad RS-232 port,
repeat the programming operation for the other LCD keypads in the system.
REMOTE PROGRAMMING – DLOAD10
The DLOAD10 program delivered with the control panel is designed for programming the
CA-5, CA-6 and CA-10 panels, as well as the RX2K, RX4K radio controllers, GSM-4 and
GSM LT-1 module and ACU-100 wireless system controller from the computer. Additionally,
the program makes it possible to create documentation of alarm systems, sets of settings for
various configurations ("patterns" which facilitate the programming of new systems), event
sets for each system, as well as to remotely operate the control panel in the same way as
with the keypads.
The program is designed for IBM PC/AT compatible computers. It works in any computer
hardware configuration in the WINDOWS (9x/ME/2000/XP) environment. It is recommended
that the program be installed on the computer hard disk.
The control panel communicates with the computer through the RS-232 interface or via the
telephone line. For telephone communication with the panel, the program uses a modem
controlled by one of the COM ports (internal or external), compatible with the HAYES "AT
Command" standard. Communication with the control panel is possible in the CCITT V.21 or
BELL 103 standard (at 300 Bps). As the control panel transmits data only with a speed of
300 bauds, the modem must support this speed of operation.
Usually a suitable modem configuration is necessary disabling the transmission
standard negotiating function and forcing the transmission speed of 300 Bps.
In order to install the program, run the D10setup.exe program from the CD, which is
delivered with the control panel. The installation completed, start the program. Access to the
program is protected with an access code. After installation, the code is 1234 and can be
changed to any sequence of 16 alphanumeric characters. As long as it has its factory form,
you can start the program (with default code 1234) by pressing the „ENTER” key (no access
code need to be entered).
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel CA-10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel CA-10 in the language / languages: English as an attachment in your email.

The manual is 0,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel CA-10

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 Additional guide - English - 60 pages

Satel CA-10 Additional guide - English - 24 pages

Satel CA-10 User Manual - English - 24 pages

Satel CA-10 Quick start guide - English - 11 pages

Satel CA-10 User Manual - German - 2 pages

Satel CA-10 User Manual - German - 4 pages

Satel CA-10 Additional guide - German - 64 pages

Satel CA-10 Additional guide - German - 24 pages

Satel CA-10 User Manual - German - 26 pages

Satel CA-10 Installation Guide - German - 44 pages

Satel CA-10 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info