CA-10 Installer Manual 13
As the control panel is only accessible to the service, a number of protective devices is
provided to prevent hacking of the system and change of any data by unauthorized persons.
All the data exchanges are authorized by changing the access codes and the data are
encoded.
The DOWNLOADING can be particularly useful to installation firms engaged in servicing
many alarm systems. Then the user suggested inspections and modifications of software will
not necessarily require troublesome and costly traveling they will be carried out with a
computer via the telephone line. Such a method of customer service and technical control of
customer systems will allow creation of alarm equipment services at an advanced and
professional level.
INSTALLATION OF THE CONTROL PANEL
Description of control panel main board
The control panel main board contains electronic components sensitive to
electric charges. Prior to installation, these charges must be removed. During
installation, avoid touching any elements on the control panel main board.
Explanations for Fig. 1:
1. The Battery cables connect the red one to the battery terminal “+” and the black one to
the battery terminal “-“. The battery circuit is protected with a 2.5 A polymer fuse. Metal
connectors, which come with the control panel, can be used for connecting cables to the
battery (bolted connection, e.g. 17 Ah battery). Owning to that the battery cables lugs
should not be cut off.
2. The J20 pins are used for setting the battery charging current:
350 mA – pins shorted,
700 mA – pins open.
3. The RJ socket for connection of the control panel RS-232 port to the computer.
The RS-232 port is intended for programming the alarm system parameters from the
computer. For programming, a cable available in the kit designated DB9F/RJ-KPL is
required.
Notes:
Do not short or touch the connector pins with your fingers.
Prior to connecting the cable, the installer should first remove the electrostatic charge
e.g. touching a grounded fixture (a faucet or a heater) with the top of his hand.
It is recommended that the cable be first connected to the control panel, and then to the
computer.
The cable connecting the RS-232 ports may be up to twenty meters long.
4. The DIALER LED is on during telephone messaging by the panel, and blinks during
pulse dialing of the telephone number.
5. The J19 RESET pins make it possible to start the service mode without entering any
service code. This function can be disabled by the installer with software means (service
function FS131).
6. The BATTERY CHARGE LED situated next to the „J19” pins is on when the battery status
is being tested by the module and during charging of discharged battery. CA-10 tests the
presence of battery every 10 seconds and every 4 minutes it tests (for several seconds)
the battery status. During testing, the processor reduces the power supply and the loads
are powered from the battery. If the battery voltage drops down to 9.5 V, the control panel
will cut off the battery in order to prevent it from a complete discharge and damage.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel CA-10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel CA-10 in the language / languages: English as an attachment in your email.

The manual is 0,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel CA-10

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 Additional guide - English - 60 pages

Satel CA-10 Additional guide - English - 24 pages

Satel CA-10 User Manual - English - 24 pages

Satel CA-10 Quick start guide - English - 11 pages

Satel CA-10 User Manual - German - 2 pages

Satel CA-10 User Manual - German - 4 pages

Satel CA-10 Additional guide - German - 64 pages

Satel CA-10 Additional guide - German - 24 pages

Satel CA-10 User Manual - German - 26 pages

Satel CA-10 Installation Guide - German - 44 pages

Satel CA-10 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info