CA-10 Installer Manual 7
33 arm/disarm/clear alarm the output signals the performance of particular operations with,
respectively, one, two, or four pulses 0.16s each.
34 keypad buzzer alarm silent alarm signaling in the partition keypad.
35 power supply on armed mode it functions similarly to the arm status output, but goes on right
after starting the exit delay countdown, not after changeover from the exit delay to the armed mode
(it can be used, for example, as indicator or power supply output for microwave detectors in spaces
where people stay).
36 LED status the output can control a LED to indicate the following statuses:
- off – control panel disarmed
- steady light – control panel armed
- blinking light – the control panel armed, there was alarm or trouble
Note: If in the armed mode any zones are violated in the system, the LED will be blinking
and will only change to steady light after the violation ends.
.37 – RELAY status the output can control a relay. The output becomes active after arming, and inactive
after an alarm is triggered, a trouble occurs, or the system is disarmed.
Note: If in the armed mode any zones are violated in the system, the output will become
active after the violation ends.
38 zone trouble the output signals that the maximum zone violation time or the maximum zone no
violation time have been exceeded.
39 no guard code the output is activated by a timer programmed as the partition control TIMER,
unless a guard code is entered within the timer specified time.
40 service mode status the output is activated if the control panel service mode has been called from
any keypad.
41 battery test resultthe output whose state is updated after each battery voltage test.
Partitions
Creation of a partition consists in assigning at least 1 zone to it. The CA-10 permits
4 partitions to be created. Any outputs, telephone numbers and pager messages can be
assigned to one partition, thus enabling four independent alarm systems to be built on the
basis of one CA-10 control panel.
In the event of a few keypads being connected to the control panel, each keypad will be
hooked up to the particular partition via a special control output. The keypad connected to the
CLK1 output will belong to the partition 1, that connected to the CLK2 output – to the partition
2, etc.
Where the system comprises less keypads than partitions, individual partitions can be
operated from the existing keypads, by means of the GO TO function (when this function is
called, the keypad will for a time belong to another partition). The partition which has no
keypad, can be controlled through the zones to which the "arming" and "disarming" functions
are assigned. The state of such a partition can be signaled on the outputs.
Partitions can be defined in the following way:
partitions have no common zones – they are independent sub-systems,
some zones belong to several partitions the common zones are only armed when all
the partitions these zones belong to are armed,
all zones of one partition belong at the same time to another partition the control
panel recognizes one partition as the master, and the other as an internal one;
arming/disarming the master partition results in simultaneously
arming/disarming the
internal partition, while arming/disarming the internal partition only affects the zones within
that partition,
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel CA-10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel CA-10 in the language / languages: English as an attachment in your email.

The manual is 0,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel CA-10

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 Additional guide - English - 60 pages

Satel CA-10 Additional guide - English - 24 pages

Satel CA-10 User Manual - English - 24 pages

Satel CA-10 Quick start guide - English - 11 pages

Satel CA-10 User Manual - German - 2 pages

Satel CA-10 User Manual - German - 4 pages

Satel CA-10 Additional guide - German - 64 pages

Satel CA-10 Additional guide - German - 24 pages

Satel CA-10 User Manual - German - 26 pages

Satel CA-10 Installation Guide - German - 44 pages

Satel CA-10 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info