12 armingviolation of this zone will arm the partitions the zone belongs to.
13 silent armingviolation of this zone will arm in silent mode the partitions the zone belongs to.
14 disarmingviolation of this zone will disarm the partitions the zone belongs to.
15 no alarm actionviolation of this zone will activate the ZONE VIOLATION type outputs.
16 arming/disarming controls arming/disarming of partition to which this zone is assigned. Setting of
"PRIORITY" option allows to choose one of two different modes:
PRIORITY option enabled: zone violation will arm the partition, while end of violation will disarm the
partition ("Bistable" action),
PRIORITY option disabled: each violation of the zone will trigger partition's state between "Armed"
and "Disarmed" state ("Monostable" action).
17 delay audiblea delayed zone with the delay countdown signaling in keypads.
18 automatic bypass arming violation of this zone arms the partition the zone belongs to,
simultaneously bypassing the zones programmed as AUTO-BYPASS (see FS16 – FS19).
19 perimeter zone armed since entering the access code and confirming it with the [#] key (i.e. arming
the partition). Violation of this zone during countdown of the „exit delay” will trigger an alarm.
20 entry/exit-final acts much like the type 0 (ENTRY/EXIT) zone, but the violated zone restore during
exit delay countdown will stop the countdown and begin the partition armed mode.
Reaction time for each zone can be programmed within 0.016 s to 4.08 s.
For each of the delayed zones, an individual time delay can be set.
Each zone involves a few options to determine the reaction in particular situations.
It is possible to determine for each zone the maximum violation time (in seconds), after which
the zone will be recognized by the control panel as defective, and to determine the maximum
"no violation" time (in hours), after which the zone will be recognized by the control panel as
defective.
The zones can be selectively bypassed.
For each zone can be determined the 9 event codes to be sent to the monitoring stations.
Outputs
The CA-10 is equipped with 6 programmable outputs: 4 high-current and 2 low-current ones.
The OUT1, OUT2, OUT3 and OUT4 outputs are protected by special electronic fuses with
current limiters set at 2.2 A. The panel monitors presence of voltage, overload, and signals
trouble conditions at these outputs. 2.2 kΩ resistors must be connected in parallel to these
outputs. The above outputs supply the load with +12 V voltage.
The OUT5, OUT6 outputs (low-current, up to 50 mA) control ground of the load.
All outputs are equipped with protective devices for inductive loads and pulse interference.
For each output can be defined the operation time in seconds (from 1 to 99 seconds),
in minutes (from 1 to 99 minutes), or LATCH type (until cut off). It is possible to determine the
output polarity for active state (+12 V or 0 V on the load), and whether it should operate in
pulsed or continuous mode.
Assignment of the particular outputs can be restricted to the specific partitions/zones of the
system.
Designation of the outputs can be adapted for the needs of the alarm system controlled by
the panel. Though individual outputs differ by their design, each of them can perform one of
the following functions:
0 not used
1 burglary alarm the output starts on detecting a burglary alarm by the control panel. The alarm is
triggered by armed zones, zone tamper circuits, keypad tamper detectors, and by the user (through
the ALARM PANIC function). If the zones to which the output is to react are defined, the zone alarms
will be limited to those included in the „list of outputs” (the other alarms will be effected irrespective of
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel CA-10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel CA-10 in the language / languages: English as an attachment in your email.

The manual is 0,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel CA-10

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 Additional guide - English - 60 pages

Satel CA-10 Additional guide - English - 24 pages

Satel CA-10 User Manual - English - 24 pages

Satel CA-10 Quick start guide - English - 11 pages

Satel CA-10 User Manual - German - 2 pages

Satel CA-10 User Manual - German - 4 pages

Satel CA-10 Additional guide - German - 64 pages

Satel CA-10 Additional guide - German - 24 pages

Satel CA-10 User Manual - German - 26 pages

Satel CA-10 Installation Guide - German - 44 pages

Satel CA-10 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info