Impulse-guided circulation - Disable switch-on
After the running time of the circulation pump, the pump cannot be started again while disable switch on is
active. This prevents unnecessary permanent operation of the pump in the case of continuous dispensing. If
the hot water cools too much while disable switch-on is active, the time should be shortened.
Then select the desired time.
Menu item Parameter Factory setting
Impulse-guided circulation -
Disable switch-on
1 min - 15 mins 5 min.
Unmixed heating cycle
Optionally, you can activate or deactivate the "Unmixed cycle" function.
Menu item Parameter Factory setting
Unmixed heating cycle
Deactivated
Deactivated
Activated
Operating mode
Select the operating mode for the unmixed circuit.
Setting heating cycle mode
This is where you can select between the dif
ferent heating cycle modes. The choice is between control
according to the set "heating curve" and "fixed value regulation".
Menu item Parameter Factory setting
Operating mode unmixed cycle
Heating
As requiredCooling
Heating and cooling
After activating the unmixed mixed heating cycle, the 1st mixed heating cycle is enabled, and
after activating the 1st mixed heating cycle, the 2nd mixed heating cycle is enabled.
The descriptions of the 1st and 2nd mixed heating cycle are identical to the unmixed heating
cycle.
The mixed heating cycles each require a supply and return probe! These probes are included in the scope of
supply of the mixed REMKO heating cycle groups.
87
87


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO Smart-Control-Touch SQW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO Smart-Control-Touch SQW in the language / languages: English as an attachment in your email.

The manual is 5,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO Smart-Control-Touch SQW

REMKO Smart-Control-Touch SQW User Manual - German - 80 pages

REMKO Smart-Control-Touch SQW User Manual - Dutch - 124 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info