Installation instructions
The device is supplied in a fully op-
erational condition and is equipped
as standard with a connection pipe
linking the indoor and outdoor de-
vices, meaning that it is ready for
use. The scope of delivery includes
various accessories for mounting
the outdoor unit.
The indoor unit
The indoor unit is positioned at the
desired location with the air dis-
charge side pointing into the room.
When positioning, ensure there is
a minimum gap of 20 cm around
the device.
Connector pipes
The connector pipes can be
laid through a tilted window
or through a gap in the door.
The connector pipe can be sepa-
rated from the indoor unit, mean-
ing that there is the additional
option of fitting it to a wall open-
ing (Ø min. 60 mm).
Please note the following information
when laying the connector pipes:
The connector pipes may not
be jammed in or kinked.
There may not be any ten-
sion of other mechanical stress
exerted on the connector pipes.
The pipe insulation and the
protective jacket may not be
damaged.
Outdoor component
The outdoor unit expels the heat
from the room into the outside air.
In order to do so, the outdoor unit
can be positioned on the ground
or mounted on an external wall.
Installation on the ground
It is not necessary to use any
mounting accessories when install-
ing the outdoor unit on a patio or
balcony.
The outdoor unit should be po-
sitioned vertically and protected
from direct sunlight. A minimum
gap of 20 cm should be main-
tained from the air discharge side
to the wall.
It must be ensured that the air can
be discharged freely (min. 50 cm
gap to any obstacles).
The connecting pipe is fed through
a gap in the window or door
(Fig. 2 and 3).
20 cm
20 cm
3 Example assembly outdoor unit
2a Absence of minimum gap
2 Minimum clearance to wall
4. Take the condensate drain hose
on the back of the indoor unit
out of its bracket and remove
the plug.
5. Allow the condensate to drain
downwards into a drain or con-
tainer.
Ensure that the external
container does not overflow.
This could result in water
damage.
!
CAUTION
6. Switch the unit on by means of
the "I / 0" button.
7. Set the temperature selection
switch to the lowest nominal
temperature.
8. Set the "MODE" button to the
lowest fan speed "LO".
7
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RKL490 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RKL490 DC in the language / languages: English as an attachment in your email.

The manual is 1,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RKL490 DC

REMKO RKL490 DC User Manual - German - 16 pages

REMKO RKL490 DC User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info