The system can be operated by means of the control panel on the device or via the standard infrared remote
control unit. The functional operation of the buttons among themselves is identical, however, the designation
can vary. The batteries must be correctly inserted before the infrared remote control is used.
Operation
Legend
"ON / OFF" button
"MODE" button
(Fan speed – mode)
The fan speed is indicated by
means of LEDs in the selected
modes AUTOHIMEDLO or
circulated air modeFAN.
LED "COMP. ON"
(Compressor operation)
The controller controls the cool-
ing output by means of switch-
ing the compressor on or off.
Compressor operation is indicat-
ed by means of the LED. If the
LED flashes, the compressor will
be activated in max. 3 mins.
Button " "
Temperature setting
The desired nominal temperature
can be set with the ▼▲ buttons
in steps of 1°C between 16 and
30°C.
On and off timer
The timer function can be used
to switch the device on or off
automatically in hourly intervals
("▼▲" buttons) by means of
pressing the "SET" button. The
function can be used to program
the switch-on timer when the
device is off and the switch-off
timer when the device is on, for
up to 24 hours. Both timers can
be deleted by means of pressing
the "RESET" button.
AUTO SWING button
The direction of the discharged
air via the oscillating fins can be
adjusted to fixed or oscillating
by pressing the "AUTO SWING"
button.
LED "DRAIN WATER"
If the pump is unable to trans-
port the collected condensate
then this is signalised via an
acoustic alarm in combina-
tion with the flashing "DRAIN
WATER" LED. The device will
be operational again after the
container is emptied by means
of the condensate drain.
Display
The display shows the set nomi-
nal temperature or the residual
time of a programmed timer.
Infrared receiver
The device receives the signals
from the infrared remote con-
trol via the sensor.
FAN button
The ventilator speed can be
adjusted by means of pressing
the "FAN" button.
Cooling mode
1. Switch the unit on by means of
the "I / 0" button.
2. Set the temperature selection
switch to the desired nominal
temperature.
3. Select the desired fan mode
to AUTO, HI, MED or LO by
means of the "MODE" button.
Circulated air
1. Switch the unit on by means of
the "I / 0" button.
2. Select FAN mode by means of
the "MODE" button.
The outdoor unit can remain in the
room in circulated air mode.
However, do not hang the outdoor
unit onto the indoor unit.
Dehumidifying mode
Position the indoor unit and the
outdoor unit in the room that is to
be dehumidified.
1. Ensure that the indoor unit can-
not extract warm air from the
outdoor unit.
2. Do not hang the outdoor unit
onto the indoor unit.
3. Please observe: The condensate
formed during dehumidifica-
tion may not be pumped to the
outdoor unit as otherwise it will
be dissipated back into the air
in the room or may run out of
the outdoor unit.
Control panel
FAN
TEMP.
ON/OFF
FUZZY
C
TIMER
MODE
infrared remote control
Infrared transmitter
REMKO RKL
6
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RKL490 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RKL490 DC in the language / languages: English as an attachment in your email.

The manual is 1,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RKL490 DC

REMKO RKL490 DC User Manual - German - 16 pages

REMKO RKL490 DC User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info