REMKO PGT (E) series
Gas connection
The use of longer hose lines
is permissible if:
- special operational reasons exist
- appropriate additional safety
measures are observed and
the hose lengths are kept
as short as possible
Hose lines must be
fundamentally protected
against chemical, thermal and
mechanical damage
In particular, torsional stress
must be avoided
The units may only be operated
out of the gas phase
The units must be serviced
by qualified persons only
Only original spare parts may
be used for repairs
Unit parts that are prone to
wear and ageing (e.g. gas
hoses) must be replaced at
regular intervals
Gas connection nipple on
the unit - G1/4 LH - KN
When selecting the hose, make
sure that the pressure class is
sufficient
The gas connection / unit
operation must take place
exclusively on the basis of
the accident prevention regulation
DGUV 79 “
Use of liquid gas”
,
as well as the respective local
construction and fire prevention
regulations.
The fuel supply must be installed
in accordance with DIN 4755 for
oil-fired warm air heaters, DVGW
Code of Practice G 600 for gas-
fired warm air heaters and TRF for
liquid gas.
The units are operated with liquid
gas in accordance with DIN 51622.
They require a constant
unit
connection pressure of 1.5 bar.
It is prohibited to exceed or
undershoot the connection
pressure.
When using longer hose lines,
consider the respective pressure
loss
Only use components that have
been tested and are suitable for
the respective purpose, such
as gas hose, pressure controller
and hose breakage protection
or leak gas protection
If possible, the length of the gas
hose should not exceed 2 m
Only pressure controllers with
a fixed outlet pressure setting
are permitted. The units may
only be operated out of the gas
phase
CAUTION
The units must not be used
below ground level
, e.g.
in basements, without suitable
gas monitoring equipment.
CAUTION
A constant unit connection
pressure of 1.5 bar (1500
mbar) must be guaranteed,
also in continuous operation.
NOTE
This does not apply
if the correct condition
is confirmed by an expert.
CAUTION
Before all work on the gas
supply and when replacing
gas cylinders, all shut-off
valves must be closed and no
ignition sources are permitted
in the immediate vicinity.
NOTE
It is prohibited to exceed
or undershoot the required
connection pressure.
All common gas cylinder sizes
are permitted for the gas
supply. However, a gas
cylinder with at least 11 kg
filling weight is recommended.
For longer operation and
nominal heat outputs above
50 kW, it is recommended that
the gas be drawn from several
gas cylinders in parallel. (Multi-
cylinder accessories set)
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO PGT 60E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO PGT 60E in the language / languages: English as an attachment in your email.

The manual is 1,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO PGT 60E

REMKO PGT 60E User Manual - German - 28 pages

REMKO PGT 60E User Manual - Dutch - 24 pages

REMKO PGT 60E User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info