14. Adjust the ignition and
ionisation electrode
in accordance with the sketch
and tighten the clamping screw
4 of the electrode bracket.
The tip of the ionisation
electrode must be in
the vicinity of the flame.
15. Carefully refit all parts of
the unit in reverse order.
Disassembling and cleaning
the gas burner
1. Switch off the gas supply to
the unit and unplug the power
plug from the mains socket.
2. Remove the protective outlet
grille, exterior cladding and
inspection cover.
3. Undo the clamping screw 5
of the nozzle holder.
4. Remove the ignition cable from
the ignition electrode.
5. Detach the ionisation cable from
the ionisation electrode. Be
aware of the cap nut and spring
washer!
6. Loosen the clamping screw 4
on the electrode bracket and
carefully draw out the ignition
and ionisation electrode.
7. Carefully remove any adhered
deposits from the ignition and
ionisation electrode.
8. Detach the fastening screws
of the gas burner and remove
the complete gas burner from
the unit.
9. Carefully clean the gas burner
with a suitable brush and
possibly compressed air.
10. Clean the gas nozzle if
necessary.
Do not use any sharp-edged
objects!
11. Carefully remove deposits
or soiling in the unit base.
12. After all cleaning work on
the gas burner, carefully refit
all parts in reverse order.
13. After using the gas nozzle,
tighten clamping screw
5 again.
Unit type A B
PGT 30
approx. 3 mm approx. 15 mm
PGT 60
approx. 3 mm approx. 15 mm
PGT 100
approx. 3-4 mm
approx. 30 mm
Legend:
1 = Gas burner
2 = Ionisation electrode
3 = Ignition electrode
4 = Clamping screw (electrodes)
5 = Clamping screw (gas nozzle)
1
4
2
3
5
A
B
Gas burner
for example with:
Soap solution
or
leak detection
spray.
Check the inlet and outlet grille
for contamination on a regular
basis
Check hoses and seals for
damage on a regular basis
Replace damaged hoses, seals,
etc. immediately
Clean the gas burner, gas
nozzle and the combustion air
openings regularly
Check ignition and ionisation
electrodes regularly and adjust
and clean if necessary
NOTE
Adjustment and maintenance
work may only be carried out
by authorised and qualified
technicians.
CAUTION
An electrical safety check must
be carried out in accordance
with VDE 0701 after any work
on the units.
NOTE
Replace defective or damaged
parts immediately and
exclusively with original spare
parts.
NOTE
A strongly yellowy flame
indicates an inadequate
fresh air supply or dirt inside
the unit.
CAUTION
A functional inspection of
the entire unit including leak
testing of all gas-conveying
connections must be
conducted
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO PGT 60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO PGT 60 in the language / languages: English as an attachment in your email.

The manual is 1,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO PGT 60

REMKO PGT 60 User Manual - German - 28 pages

REMKO PGT 60 User Manual - Dutch - 24 pages

REMKO PGT 60 User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info