587703
16
Zoom out
Zoom in
Previous page
1/32
Next page
Selection of the installation
location
Interior unit
The indoor unit is designed for
horizontal wall installation above
doors. However, it can also be
used on the upper wall area can
be used (min. 1.75 m above the
surface of the floor).
Outdoor component
The outdoor component is
designed for horizontal installation
on a base in outdoor areas.
It should be placed on level, flat
and firm surface. The unit should
also be secured against tipping
over. The outdoor component can
be set up outside as well as inside
a building. For external installation,
please observe the following notes
to protect the unit from weather
conditions.
Wall openings
A wall opening of at least
70 mm diameter and 10 mm
slope from the inside to the
outside must be made for each
indoor unit
We recommend that the inside
of the opening is padded or
lined, e.g. using a PVC pipe,
to prevent the lines being
damaged.
After installation, the wall
opening should be closed off
with a suitable sealant. Do not
use materials containing cement
or lime!
Installation material
The indoor unit is fastened using
a wall bracket and 4 threaded screws
(provided by the customer).
The outdoor component is
attached to the wall with 4 screws
and a wall bracket or on a pedestal
secured to the ground.
Minimum clearance to snow
20 cm
Snow
Windbreak
Wind
Lines in the wall throughput
Control line
Condensation line
Injection line
Suction line
PVC tube
Rain
The unit should be at least 10 cm
off the ground when mounted on
the roof or ground. A pedestal is
available as an accessory.
Sun
The condenser on the outdoor
component gives off heat.
Exposure to direct sunlight further
increases the temperature of the
fins and reduces the heat released
by the finned heat exchanger.
The outdoor component should
be installed on to the north
side of the building whenever
possible. If necessary, take
measures to provide sufficient
shade (responsibility of customer).
This can be accomplished with a
small roof. However, the measures
taken should not affect the flow of
warm outlet air.
Wind
If the unit is being installed in
windy areas, ensure that the
warm outlet air discharges in the
main wind direction. If this is not
the case it may be necessary to
install a windbreak (provided by
the customer). Ensure that the
windbreak does not adversely
affect the air supply to the unit.
Snow
The unit should be wall-mounted
in areas of heavy snowfall.
Installation should then be at least
20 cm above the expected level
of snow to prevent snow from
entering the outdoor component.
An optional wall bracket is
available as an accessory.
REMKO ML...DC - ARCTIC
16
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO ML522 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO ML522 DC in the language / languages: English as an attachment in your email.

The manual is 1,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO ML522 DC

REMKO ML522 DC User Manual - German - 32 pages

REMKO ML522 DC User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info