Technical data
Series
ML 262 DC ML 352 DC ML 522 DC
Operational mode Wall / room air conditioner combination for cooling and heating
Nominal cooling output
1)
kW 2,68 (0,67-3,52) 3,52 (0,72-3,96) 5,24 (1,49-6,45)
Nominal heating output
2)
kW 3,15 (0,70-3,75) 4,29 (0,82-4,69) 5,94 (1,55-6,74)
Energy efficiency class, cooling
1)
A A A
Energy efficiency ratio EER
1)
3,31 3,29 3,23
Energy efficiency class, heating
2)
A A A
Coefficient of performance COP
2)
3,71 3,67 3,61
Power consumption, annual, (500h) K / H 405 / 400 535 / 580 510 / 960
Operating range (room volume), approx. 80 110 160
Refrigerant R 410A
4)
Power supply V/Hz 230 / 1~ / 50
Nom. electrical power consumption, cooling
1)
kW 0,81 ( 0,19-1,18) 1,07 (0,21-1,38) 1,62 (0,38-2,32)
Nom. electrical power consumption, heating
2)
kW 0,81 (0,19-1,10) 1,17 (0,21-1,18) 1,64 (0,35-2,05)
Elec. nominal power consumption cooling
1)
A 3,70 (0,9-5,2) 4,40 (1,0-6,2) 7,09 (1,8-10,2)
Elec. nominal power consumption heating
2)
A 3,60 (0,9-5,0) 4,5 (1,0-6,6) 7,25 (1,6-9,2)
Elec. starting current, max. A 8 10 10
Refrigerant connection - injection line
Inches
(mm)
1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Coolant connection - suction line
Inches
(mm)
3/8 (9,52) 3/8 (9,52) 1/2 (12,70)
Max. operating pressure kPa 4200 / 4200
Corresponding indoor unit
ML 262 DC IT ML 352 DC IT ML 522 DC IT
Serial number 802W6000 -... 808W6000 -... 809W6000 -...
Adjustment range, room temperature °C +17 to +30
Operating range °C +16 to +31
Air flow volume per speed setting m³/h 500/420/350 550/450/370 800/700/600
Sound pressure level per speed setting
3)
dB(A) 29/34/39 31/37/40 37/39/42
Protection class IP X0
Condensate connection mm 14 14 14
Dimensions - Height mm 275 275 275
Width mm 790 790 940
Depth mm 190 190 200
Weight kg 8,5 8,5 11,0
Corresponding outdoor component
ML 262 DC AT ML 352 DC AT ML 522 DC AT
Operating range - cooling °C +5 to +50
Operating range - heating °C -7 to +25
Air flow rate, max. m³/h 1700 1850 1500/2200
Protection class IP 24
Sound pressure level, max.
3)
dB(A) 50 51 54
Refrigerant, basic quantity kg 0,83 0,94 1,10
Refrigerant, additional quantity > 5 m g/m 30 30 30
Refrigerant line, max. length m 20 20 25
Refrigerant line, max. height m 8 8 10
Dimensions - Height mm 590 540 590
Width mm 760 730 760
Depth mm 270 270 270
Weight kg 38,0 39,0 39,5
Serial number 802W9000-... 808W9000-... 809W9000-...
EDP no. 1632265 1632355 1632525
1) Air inlet temperature TK 27°C / FK 19°C, outdoor temperature TK 35 °C, FK 24 °C, max. air flow volume, 5m line length
2) Air inlet temperature TK 20°C, outdoor temperature TK 7°C, FK 6°C, max. air flow volume, 5m line length
3) Distance 1 m free field
4) Contains greenhouse gas according to Kyoto protocol
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO ML522 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO ML522 DC in the language / languages: English as an attachment in your email.

The manual is 1,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO ML522 DC

REMKO ML522 DC User Manual - German - 32 pages

REMKO ML522 DC User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info