587581
18
Zoom out
Zoom in
Previous page
1/28
Next page
Minimum clearances
Observe the minimum clearances
to allow access for maintenance
and repair work and facilitate
optimum air distribution.
Connection options
The following connection options
are available for the condensation
pipes and control cables.
Connection options
4
1 Exit on wall, right
2 Exit through wall, right
3 Exit through wall, left
4 Exit on wall, left
Rear view
1
2 3
Minimum clearances
All values in mm
1000
1000
1000
1000
300
Important points prior to
installation
When installing a complete
system, take into account the
manuals for the indoor unit and
outdoor component.
Transport the unit in its original
packaging as close as possible
to the installation location.This
avoids transportation damage.
Check that the packaged
contents are complete and
inspect the unit for any visible
signs of transportation damage.
Immediately notify any
deficiencies to the contractual
partner and forwarding agent.
Lift the unit by its corners
and not the refrigerant or
condensation connections.
Insulate the refrigerant pipes
(injection and suction pipe),
valves and connections to make
them tight against vapour
diffusion. If necessary, also
insulate the condensation pipe.
Select an installation location
which allows air to freely flow
through the inlet and outlet
(see section "Minimum
clearances").
Do not install the unit
adjacent to any hotspots. Unit
performance will be impaired if
installed next to hotspots.
Installation material
The indoor unit is fastened by the
back of its housing using 4 screws
to be provided by the customer.
Selecting the installation
location
The indoor unit is designed for
horizontal wall-mounting high up
on walls (min. 1.75 m above the
level of the floor).
Installation instructions for qualified personnel
Use caps or adhesive tape to
seal off the open refrigerant
pipes and prevent the ingress of
humidity. Never kink or push in
the refrigerant pipes.
Only use the union nuts
supplied with the refrigerant
pipes. These should only
be removed shortly before
connecting the refrigerant
pipes.
Establish all electrical
connections in accordance with
the relevant DIN- and VDE
standards.
Ensure the electrical cables
are properly connected to the
terminals,
otherwise there is a risk of fire.
REMKO ATY
18
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO ATY351 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO ATY351 in the language / languages: English as an attachment in your email.

The manual is 1,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO ATY351

REMKO ATY351 Additional guide - German - 1 pages

REMKO ATY351 User Manual - German - 28 pages

REMKO ATY351 User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info