Set up inside a building
■
Make sure there is sufficient
heat discharge, if the exterior
unit is set up in the basement,
the attic, in secondary rooms or
hallways (Fig. 7).
■
Install an additional fan with
the same air volume flow as
the exterior unit installed in the
room, which can compensate
for any possible additional
pressure losses through air
channels (Fig. 7).
■
Ensure a continuing unimpaired
air supply from outside, if
possible through opposite,
sufficiently large air openings
(Fig. 7).
Minimum clearances
The minimum clearances are to
be provided for maintenance and
repair work and for optimum air
distribution.
ATY 260 AT ATY 350 AT
A 100 mm 100 mm
B 700 mm 700 mm
C 400 mm 400 mm
D 100 mm 100 mm
E 300 mm 300 mm
■
Observe the static and
other construction technical
regulations and conditions
regarding the building and,
if necessary, provide sound
insulation.
Minimum clearances
E
C
B
A
D
1000
1000
1000
1000
Air inlet
Air
discharge
Warm air Cold
fresh air
Light well
Exterior unit
Warm air
Light well
Additional fan
7 Set up inside the building
300
REMKO ATY
20
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO ATY350 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO ATY350 in the language / languages: English as an attachment in your email.

The manual is 1,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO ATY350

REMKO ATY350 Additional guide - German - 1 pages

REMKO ATY350 User Manual - German - 32 pages

REMKO ATY350 User Manual - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info