TREATMENT TIPS
Body Treatment
For best results, avoid overlapping ashes. This helps prevent exposure to more energy than is necessary to
suppress hair growth. It also ensures that you get the maximum use of the Bulb.
For the most eective results, always use the highest intensity operating mode that does not cause discomfort on
the skin. The level you use should feel warm on your skin, but should never cause discomfort.
You may notice that bony areas, such as elbows, shins and ankles, are more sensitive during treatment. This is
normal and should not be cause for alarm. To avoid this sensitivity, try stretching the skin away from the bony area
during treatment.
Facial Treatment
Test on a Patch of Skin – since facial skin tends to be more sensitive, make sure you test on a small patch before
proceeding. See section ‘Test the i-LIGHT on your skin’ for more details.
Use a Mirror to Guide your Treatments – using a mirror for a good view of the area to be treated and to help ensure
you avoid treating the lips or any other dark spots. If the reected light is unpleasant, you may want to close your
eyes before each ash.
Stretch Skin for Better Skin Contact – the contours of the skin may make it dicult for the skin contact sensors to be
fully depressed in certain areas. You may nd it easier to try and wrap your upper lip over your teeth or use your
tongue to stretch your cheeks for better skin contact.
POST TREATMENT CARE
After treatment, you may experience slight redness or a warm sensation on your skin. This is normal and will disappear
over time. To avoid irritation to your skin after a treatment, take the following precautions:
Avoid sun exposure for 24 hours after a treatment. Protect the skin with SPF 30 for 2 weeks after each treatment.
Do not prolong sun exposure such as sunbathing, using a tanning bed, or self-tan for at least 2 weeks after the last
treatment.
After treatment, keep the area clean and dry and drink plenty of water to keep skin hydrated.
Do not take hot baths, showers, or use steam rooms and saunas until any redness or skin sensitivity has returned to
normal.
Do not depilate (waxing, plucking, threading or creams) during the treatment – shaving is acceptable as long as you
avoid shaving 24 hours after each treatment.
Do not use bleaching creams or perfumed products for 24 hours after treatment.
300,000 FLASH BULB
The bulb will deliver 300,000 ashes in its lifetime.
The bulb in this device is guaranteed to last for the entire guarantee period as stated on the guarantee card
supplied with this product.
When the bulb has reached 99% of its possible lifetime, one of the LEDs on the side of the hand piece will illuminate
red during power up.
When the bulb life is exhausted you will no longer be able to use the device.
CLEANING YOUR iLIGHT DEVICE
F CAUTION Before cleaning your i-LIGHT, make sure that the device is switched OFF and the power cord is
disconnected from the device.
Regular cleaning helps to ensure optimal results and a long life for the i-LIGHT device.
To clean the Flash Window, use only the lint-free cloth included with your i-LIGHT device. Take care not to scratch or
chip the Flash Window. Scratches and chips can reduce the eectiveness of the unit.
For stubborn stains on the ash window, dampen a cotton swab with surgical spirit or rubbing alcohol, apply to the
ash window and clean gently with the lint-free cloth provided.
ENGLISH
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remington IPL8500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remington IPL8500 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish, All languages as an attachment in your email.

The manual is 2,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info