30
Gas distribution pipe
Gas multi-block
Fig. 20 Differential pressure measuring points (boiler with 11 to 19 sections)
blue
blue
burner
14. Measure the CO
2
percentage at full load, in the
ue pipe, directly above the casing. The measured
value must be compared with the value indicated in
the table. If the measured value deviates from the
value mentioned in the table, it can be adjusted by
turning the V-controller (see gure 21 or 22) on the
gas multi-block.
Please note:
Only turn the V-controller at full load and only turn
the N-controller at part load. Turning the controller
slightly may have a large infl uence on the load
and the CO
2
percentage.
The CO
2
percentage increases by turning this con-
troller clockwise. If, after turning the V-controller,
the value corresponds with the table value, or falls
at least within the specifi ed tolerance, check the
following points:
a) the combustion quality by looking through the
sight holes in the end sections.
Check that - the ames do not blow off,
- the burner surface is not red hot.
b) the differential pressure between the measuring
points pF and pG (see g. 19 for 7 and 9 sections
and fi g. 20 for 11 to 19 sections). See table on
the boiler for value.
If, when checking the points mentioned under a) and
b), major deviations are found, these can be corrected
by turning the V-controller.
The CO
2
percentage should remain within the toler-
ance mentioned in the table on the boiler.
15. Switch the boiler to part load by selecting option
'Load minimum' with the ' ' button and confi rming it
with the ' ' button.
Measure the CO
2
percentage, compare the measured
value with the table value. If it deviates more from
the desired value than the tolerance mentioned in
the table, this value may be adjusted by turning the
N-controller (fi gure 21 or 22) on the gas multi-block. If,
after turning the N-controller, the CO
2
percentage cor-
responds with the table value or in any case remains
within the mentioned tolerance, check the following
points:
a) the combustion quality by looking through the
sight holes in the end sections.
Check that the ames do not blow off (the burner
surface may evenly burn red-hot).
b) the differential pressure between the measuring
points pL and pG (see fi g. 19 or 20). See table
on the boiler for value.
If, when checking the points mentioned under a) and
b), major deviations are found, these can be corrected
by turning the N-controller.
The CO
2
percentage should remain within the toler-
ance mentioned in the table on the boiler.
black
black
gas = PL+PG
air = PL+PF
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Gas 3002 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Gas 3002 in the language / languages: Dutch as an attachment in your email.

The manual is 1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Remeha Gas 3002

Remeha Gas 3002 User Manual - German - 28 pages

Remeha Gas 3002 Manual - Dutch - 2 pages

Remeha Gas 3002 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info