Maintenance & Servicing
Maintenance requirements
To ensure the continued optimum performance of the Remeha Flexistor it should be regularly
maintained. This is of particular importance in hard water areas or where the water supply
contains particulate matter. Maintenance should be carried out by a competent person and any
replacement parts used should be authorised Remeha Flexistor spare parts. It is recommended
that maintenance is carried out every 12 months and includes the checks detailed below.
In hard water areas consideration should be given to periodically descaling the immersion heater
elements. To do this the Remeha Flexistor unit will need to be drained.
Check operation of Safety Valves
Slowly open the Temperature and Pressure Relief Valve by twisting its cap for a few seconds. Check
water is discharged and that it ows freely through the tundish and discharge pipe work. Check valve
reseats correctly when released.
NOTE: The water discharged may be very hot.
Repeat the procedure for the Pressure Relief Valve.
Inspection
The immersion heater boss can be used as an access for inspecting the cylinder internally.
Clean the strainer
The strainer is incorporated within the Pressure Reducing Valve housing of the Valve. To inspect and
clean the strainer:
1. Turn o󰀨 the isolating valve prior to the Pressure Reducing Valve or the main stop cock to the
system.
2. Open the lowest hot tap in the system to relieve the system pressure.
3. Using a spanner unscrew the pressure reducing cartridge and remove the moulded housing.
The strainer will be removed with the cartridge.
4. Wash any particulate matter from the strainer under clean running water.
5. Replace the strainer and screw the Pressure Reducing Valve cartridge into the moulded
housing.
6. Close hot tap, turn on isolating valve or main stop cock to the system. Check for leaks.
Draining the Cylinder
Switch o󰀨 the electrical supply to the immersion heater(s) and primary heat source, if used. Turn o󰀨
the mains water supply to the Remeha Flexistor unit. Attach a hosepipe to the drain valve having
su󰀩cient length to take water to a suitable discharge point below the level of the unit, at least one
metre below the unit is recommended. Open hot water tap nearest to the Remeha Flexistor to
relieve the system pressure. Open drain valve. If water fails to drain from the Remeha Flexistor vent
the unit by manually opening the Temperature / Pressure Relief Valve.
Relling system
DO NOT switch on the immersion heater(s) or primary heat source until the system has been
completely relled.
Close the drain valve. With the hot tap open, turn on mains water supply. When water ows from the
hot tap allow to ow for a short while to purge air and to ush through any disturbed particles. Close
hot tap and then open successive hot taps in system to purge any air. The electrical supply can now
be switched on.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Flexistor at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Flexistor in the language / languages: English as an attachment in your email.

The manual is 2.7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info