Chapter 4: Calibration 33
Adjust to SOG
The Adjust to SOG screen is displayed only if SOG data is available
from SeaTalk. The current SOG is displayed in the bottom section of
the display (SG12.8 in the illustration), and the current speed registered
by the instrument, as large figures in the middle section of the display
(12.3 in the illustration).
It is recommended that, if you are running in slack tide conditions, you
press the reset key for 3 seconds, to accept the SOG as the current
speed.
If you do not wish to accept SOG as the current speed, press the trip
and reset keys together to select the Cal factor adjust display.
Cal factor adjust
The Cal factor adjust screen enables you to manually adjust the
calibration factor. It shows the current calibration factor in the bottom
section of the display (CF 1.00 in the illustration), and the current speed
as large figures (12.3 in the illustration).
Use the trip or reset key to adjust the calibration factor so that the
current speed is the speed through the water.
If SOG data is available from SeaTalk, you can turn to the Adjust to
SOG screen by pressing the trip and reset keys.
Note: If neither of the above methods gives satisfactory results, carry
out the Speed calibration procedure (part of Intermediate calibration).
Set temperature units
Select either °C or °F, as required.
Temperature calibration
Set the display to show the current water temperature.
Timer alarm buzzer
Switches the count-up and race-start timer audible alarm on the ST60
Tridata instrument being calibrated, on and off.
040_3c04.p65 06/04/01, 10:2133
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Raymarine ST60 Tridata Instrument at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Raymarine ST60 Tridata Instrument in the language / languages: English as an attachment in your email.

The manual is 0,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Raymarine ST60 Tridata Instrument

Raymarine ST60 Tridata Instrument User Manual - German - 66 pages

Raymarine ST60 Tridata Instrument User Manual - Dutch - 66 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info