Chapter 4: Calibration 31
If you want to apply a keel offset, adjust the displayed reading until
the appropriate negative offset value is shown.
Shallow alarm lock
When set to on, prevents alteration to the shallow depth alarm
threshold.
Speed
To calibrate the speed functions:
1. With the User calibration entry screen displayed, press the speed
key.
2. Referring to the User calibration - speed illustration, carry out the
calibration procedure. Use the speed key to cycle from screen to
screen and the trip and reset keys to set the required values at
each screen (except Adjust to SOG display).
Set speed units
Select either KTS (knots), MPH (miles per hour) or KMH (kilometres per
hour), as required.
Set speed resolution
Select resolution of either 0.01 or 0.1 as required.
Set log units
Select either NM (nautical miles), SM (statute miles) or KM
(kilometres), as required.
Setting the correct speed
Set the displayed (current) speed using one of the following methods:
Use the Adjust to Speed Over Ground (SOG) screen to
automatically set the current speed to SOG (if available from
SeaTalk). You must be running in slack tide conditions to
successfully use this method.
Manually apply a calibration factor by means of the Cal factor
adjust screen, to set the displayed speed value to your best estimate
of the vessels speed.
040_3c04.p65 06/04/01, 10:2131
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Raymarine ST60 Tridata Instrument at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Raymarine ST60 Tridata Instrument in the language / languages: English as an attachment in your email.

The manual is 0,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Raymarine ST60 Tridata Instrument

Raymarine ST60 Tridata Instrument User Manual - German - 66 pages

Raymarine ST60 Tridata Instrument User Manual - Dutch - 66 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info