815528
29
Zoom out
Zoom in
Previous page
1/40
Next page
29 02/237022-802K
VACUUM
SWITCH
SNAP
DISC #2
CAPACITOR FEED
MOTOR
SNAP
DISC #1
CONVECTION
BLOWER
COMBUSTION
BLOWER
SNAP
DISC #3
FUSE
RESET
BUTTON
CALL
LIGHT
THERMOS TAT
BLOCK
HEAT OUTPUT
SWITCH
THERMOCOUPLE
IGNITOR
YELLOW
YELLOW
RED
RED
ORANGE
WHITE
BLUE
BLUE
PURPLE
GRAY
BLACK
BLACK
BLACK
BLACK
HOPPER
SWITCH
Figure 29.1
20. Vacuum Switch: The vacuum switch is located on the
lower right side of the appliance behind left access
panel. This switch turns the feed system on when
vacuum is present in the rebox. The vacuum switch is
a safety device to shut off the feed motor if the exhaust
or the heat exchanger system is dirty or plugged or if
the rebox door is open.
21. Wiring Schematic: See Figure 29.1 below
The power outlet is located on the right rear of the appliance
beneath the heat output switch and reset button.
17. Snap Disc #1 (Convection Blower) 110°F: Snap disc
#1 is located on the right side of the rebox. There
are 2 purple wires connected to it. This snap disc turns
the convection blower on and off as needed. Power
is always present at snap disc #1 if the appliance is
powered up.
18. Snap Disc #2 (Fuel Delivery Interrupt) 250°F
: Snap disc
#2 is located on the back side of the feed drop tube.
There is 1 orange wire and 1 black wire connected to it.
This snap disc will turn off the feed system, which will
turn off the appliance if an over re condition should
occur or if the convection blower should fail to operate.
If this occurs the snap disc with automatically reset
itself.
19. Snap Disc #3 (Burn Back Protector) 250°F
: Snap
disc #3 is mounted on the back of the auger tube in
the center of the appliance and has a reset button. To
access it remove the right side panel. If the re tries
to burn back into the feed system or push exhaust up
the feed tube, this snap disc will shut the entire system
off. This disc must be manually reset. Power is always
present at snap disc #3 if the appliance is powered up.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Quadra-Fire Castile - Pellet - Insert at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Quadra-Fire Castile - Pellet - Insert in the language / languages: English as an attachment in your email.

The manual is 9.65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Quadra-Fire Castile - Pellet - Insert

Quadra-Fire Castile - Pellet - Insert User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info