1. Make sure that the AC circuit breaker is in the OFF position. The generator may be hard
to start if a load is connected.
2. Turn the fuel valve lever to the ON position.
3. The choke must be closed if the engine is cold, push the choke rod to the Choke-position.
4. Turn the engine switch to the START position.
5. Pull the starter grip lightly until resistance is felt, then pull briskly.
11.2 Connecting electric tools/appliances
Insert the plug(s) of the electrical appliance(s) into the power socket. (lift the protective lid of
the socket and plug in the load.
CAUTION:
Be sure the electric appliance is turned off before plugging in.
Be sure the total load is within generator rated output.
Be sure the socket load current is within socket rated current.
NOTE:
When the circuit breaker is switched off during operation, the generator was overloaded or a
short circuit occurred (example. connected machine may be defect).
Stop the generator immediately, check the connected power, diminish when it exceeds the
rated generator output. Check the power tool. Allow to cool down for a few minutes before you
switch the circuit breaker back to “ON”.
Most motorized appliances require more than their rated power for startup.
Do not exceed the current limit specified for any one receptacle. If an
overloaded circuit causes the AC circuit breaker or AC circuit protector to
switch OFF, reduce the electricalload on the circuit, wait a few minutes and
then reset the AC circuit breaker or AC circuit protector.
11.3 Stopping
NOTE: Before starting the engine, disconnect all loads from the generator.
1. Turn the AC circuit breaker to the OFF position.
2. Turn the engine switch to the OFF position.
3. Turn the fuel valve lever to the OFF position.
Emergency stopping: Turn the engine switch to “OFF”. The engine will stop
immediately.
11.4 Operating time
Depending on the type you’re using, if you start with a full tank and let it run continuously, your
generator will run approximately :
Fuel tank capacity
POWX510
15 liters
The Petrol level display on top of the fuel tank shows you approximately how much petrol
there is left in the tank.
11.5 Ground system
This generator has a ground system that connects the generator frame components to the
ground terminals in the AC output receptacles. The system is not connected to the AC neutral
wire.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Powerplus POWX510 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Powerplus POWX510 in the language / languages: English as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Powerplus POWX510

Powerplus POWX510 User Manual - German - 17 pages

Powerplus POWX510 User Manual - Dutch - 17 pages

Powerplus POWX510 User Manual - French - 17 pages

Powerplus POWX510 Additional guide - All languages - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info