Copyright © 2015 VARO P a g e | 8 www.varo.com
Check the oil level before each use with the generator on a level surface and the engine
stopped.
Use 4-stroke motor oil.
SAE 10W-30 is recommended for general, all-temperature use. Other viscosities shown in
the chart may be used when the average temperature in your area is within the indicated
range. (Fig. 3-> A: SAE Viscosity Grades, B: Ambient temperature)
1. Remove the oil filler cap and wipe the dipstick clean. (Fig. 4)
2. Check the oil level by inserting the dipstick into the filler neck without screwing it in.
3. If the level is low, fill to the top of the oil filler neck with the recommended oil. (Fig. 5)
10.2 Fuel (Fig 6, 7)
Check the fuel gauge and refill the tank if the fuel is low.
Refuel carefully to avoid spilling fuel. Do not fill above the shoulder of the fuel strainer.
Gasoline is highly flammable and explosive and you can be burned or
seriously injured when refueling.
Stop engine and keep heat, sparks and flame away.
Refuel only outdoors
Wipe up spills immediately
Use unleaded gasoline with a pump octane rating of 86 or higher.
This engine is certified to operate on unleaded gasoline.
Unleaded gasoline produces fewer engine and spark plug deposits and extends exhaust
system life.
Never use stale or contaminated gasoline or an oil/gasoline mixture. Avoid getting dirt or
water in the fuel tank.
10.3 Air filter
The air filter prevents the entry of dust and dirt particles into the carburettor and the
combustion chamber of the motor.
Never operate the generator without the air filter! This would result in highly increased wear of
the engine!
A dirty air filter results in reduced engine efficiency, so the filter cartridge must be cleaned
regularly.(more often when used in dusty environments.)
11 OPERATION
DANGER: Before operation connect your generator to earth! This way you
will avoid static charges (possible electric shock) and will enable protective
devices to respond (e.g. leakage current trip switches) on the appliances
being connected.
Use a shielded conducting cable with a minimum cross-section of 1.5 mm² to connect your
generator to an earthing point (e.g. a water or heating pipe). Connect the conductor to the
earthing connection on your generator and tighten it securely.
CAUTION: The generator has been shipped without engine oil. Fill with oil
or it will not start.
11.1 Starting the engine
NOTE: Before starting the engine, disconnect all loads from the generator.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Powerplus POWX510 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Powerplus POWX510 in the language / languages: English as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Powerplus POWX510

Powerplus POWX510 User Manual - German - 17 pages

Powerplus POWX510 User Manual - Dutch - 17 pages

Powerplus POWX510 User Manual - French - 17 pages

Powerplus POWX510 Additional guide - All languages - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info