F01MINI2
Toggle enabled state of modem initialization string.
F01MINIx , where x is 0 or 1 depending on
the current enabled state of the modem
initialization string.
F01MINI?
Query enabled state of modem initialization string.
F01MINIx , where x is 0 or 1 depending on
the current enabled state of the modem
initialization string.
8.92. MINISTR -- Set Modem Initialization String
This command is used to set or query the modem initialization string. The string can be a maximum of 32
characters long. The recommended modem initialization string for the Vortex is:
ATF1E0&B1S0=2
This can be set via the following command.
F01MINISTRATF1E0&B1S0=2
Whether or not the modem initialization string is sent at power-up is controlled via the
MINI command.
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved each time it
is changed. It will retain its value after power-down. Since this command writes to non-volatile memory, there
will be a delay before an acknowledgment is returned.
Example Description Status Message
F01MINISTRATF1E0&B1S0=2
Set modem initialization
string to ATF1E0&B1S0=2.
F01MINISTRATF1E0&B1S0=2
F01MINISTR?
Query current modem
initialization string.
F01MINISTR<string> , where <string> is
the current modem initialization string. If this
command was sent after the above example,
then the status message would be
F01MINISTRATF1E0&B1S0=2 .
8.93. MMUTE -- Mute Crosspoint in Main Matrix or Submatrix
This command sets or queries the mute status of one or more crosspoints in either the main matrix or one of the
EF Bus submatrices.
This command is a matrix boolean command. See
Section 6.4 and Section 6.1 for more information on this type
of command.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message
77


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Polycom Vortex EF2280 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Polycom Vortex EF2280 in the language / languages: English as an attachment in your email.

The manual is 0,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Polycom Vortex EF2280

Polycom Vortex EF2280 User Manual - English - 62 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info