Query automatic logic output status messages.
F01LOENx , where x is 0 or 1 depending on the
current setting of LOEN.
8.77. LOK -- Delete One or All Logic Output Pin Commands
This command "kills" or deletes all commands for a given logic output pin. In other words, the commands
associated with
LOA and LOD will be deleted for the specified logic output. A wildcard character can also be
specified for the logic output pin, in which case the commands for all logic output pins will be deleted.
Using this command is more efficient than deleting one command or pin at a time since this command deletes
them all at once and requires fewer writes to non-volatile memory.
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved each time it
is changed. It will retain its value after power-down. Since this command writes to non-volatile memory, there
will be a delay before an acknowledgment is returned.
Example Description Status Message
F01LOK5
Delete all the commands associated with logic output pin 5. This one command is
equivalent to executing the commands 'F01LOA5, ' and 'F01LOD5, ' except that
this command is more efficient.
F01LOK5
F01LOK*
Delete all the commands associated with all logic output pins. This one command
is equivalent to executing the commands 'F01LOA1, ' and 'F01LOD1, ' for each
logic output, except that this command is much more efficient.
F01LOK*
8.78. LOM -- Mask Logic Output Pins
This command is used to mask (i.e., disable) logic output pins. The mask consists of 20 fields (one for each logic
output) that can each be set to 0 or 1. If the mask bit for a given logic output is set to 1, then the logic output
pin works normally. If the mask bit for a given logic output is set to 0, then the logic output is disabled. When a
a logic output is disabled, it is "frozen" in whatever state it is in when it is disabled. The output pin's state will not
change when the condition that drives it (via
LOA and LOD) changes. However, any changes to that pin caused
by setting the values with an
LO command will affect the output pin value. For instance, you could disable
(mask) a pin and then explicitly set its value to low with the
LO command.
When a logic output pin is re-enabled, it will be updated to the current status of whatever condition drives it (via
(
LOA and LOD).
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message
F01LOM10010110111101111111
Mask (disable) logic
outputs 2, 3, 5, 8,
and 13.
F01LOM10010110111101111111
F01LOM?
Query current logic
output mask.
F01LOMabcdefghijklmnopqrst , where a-t are
each 0 or 1 depending on the current state of the
logic output mask.
69


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Polycom Vortex EF2280 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Polycom Vortex EF2280 in the language / languages: English as an attachment in your email.

The manual is 0,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Polycom Vortex EF2280

Polycom Vortex EF2280 User Manual - English - 62 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info