This command is a boolean command. See Section 6.1 for more information on this type of command.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message
F01GATEEN0
Disable automatic gating messages.
F01GATEEN0
F01GATEEN1
Enable automatic gating messages.
F01GATEEN1
F01GATEEN2
Toggle enabled state of automatic gating
messages.
F01GATEENx , where x is either 0 or 1
depending on whether automatic gating
messages are currently disabled or enabled.
F01GATEEN?
Query enabled state of automatic gating
messages.
F01GATEENx , where x is either 0 or 1
depending on whether automatic gating
messages are currently disabled or enabled.
8.54. GMUTEO -- Mute All Outputs
The name of this command is an abbreviation of "Global Mute Outputs." Enabling this option causes all of the
physical outputs to be muted (outputs 1-8, A-D) . This muting is independent of the normal output mute
command,
MUTEO. This command is provided so that the control program can implement a "saftey mute"
feature. The idea is that if the user accidentally misconfigures the Vortex and feedback begins to occur, they can
press the saftey mute to instantly mute all outputs before they damage their equipment or ears.
This command is a boolean command. See
Section 6.1 for more information on this type of command.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message
F01GMUTEO1
Enable global output mute.
F01GMUTEO1
F01GMUTEO0
Disable global output mute.
F01GMUTEO0
F01GMUTEO2
Toggle global output mute.
F01GMUTEOx , where x is 0 or 1 depending on the current state
of the global output mute.
F01GMUTEO?
Query acknowledgement mode.
F01GMUTEOx , where x is 0 or 1 depending on the current state
of the global output mute.
8.55. ID -- Set Device ID
This command sets or queries the Device ID for the Vortex. Typically, the device ID is set from the front panel of
the Vortex, so this command is not normally used. There are restrictions involving having devices with the same
ID linked on EF Bus -- see the Vortex Reference Manual for more details.
This command is an integer command. See
Section 6.2 for more information on this type of command. The
minimum and maximum values for this command are 0 and 7, respectively.
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved each time it
is changed. It will retain its value after power-down. Since this command writes to non-volatile memory, there
will be a delay before an acknowledgment is returned.
55


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Polycom Vortex EF2280 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Polycom Vortex EF2280 in the language / languages: English as an attachment in your email.

The manual is 0,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Polycom Vortex EF2280

Polycom Vortex EF2280 User Manual - English - 62 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info