731541
9
Zoom out
Zoom in
Previous page
1/15
Next page
Manual
9
c) To exit the memory record function, press and hold the "REC" button for at least 2 seconds. The
display will revert to the current reading.
LCD Backlight ON/OFF
After turning the power ON, the "LCD Backlight" will be activated automatically. During the measurement,
press the "Backlight Button" (4-2) once to turn OFF the "LCD Backlight". Press the "Backlight Button"
once again to turn ON the"LCD Backlight" again.
6 Datalogger
Preparation before using the datalogger function
a. Insert an SD card (1 GB to 16 GB, optional) into the "SD card socket" (4-18). The front side of the SD
card should face the bottom of the case.
b. If you use the SD card with the meter for the first time, it is recommended to take care of the "SD card
Format" first.
c. Time setting
When the meter is used for the first time, the clock time should be set exactly.
d. Decimal format setting
The numerical data structure of the SD card is decimal by default, for example "20.6" "1000.53".
However, in certain countries (Europe ...) the "," is used as the decimal point, for example " 20, 6 "
"1000,53". Under these circumstances, the decimal character should be changed first.
Auto datalogger (Set sampling time 1 second)
a. Start the datalogger
Press the "REC Button (4-4) once. The LCD will show the text "REC". Then press the "Logger Button" (4-
8); " REC " will flash and the beeper will sound. At the same time, the measuring data along with the time
information will be saved to the memory circuit.
b. Pause the datalogger
When using the datalogger function, when you press the "Logger Button" (4-8) once, the datalogger
function will be paused ( stop to save the measuring data into the memory circuit temporarily). "REC" will
stop flashing.
Note: If you press the "Logger Button" (4-8) once again, the datalogger function will be carried out again
and the text "REC" will flash.
c. Finish the datalogger
When pausing the datalogger, press and hold the "REC Button" (4-4) for at least two seconds, the "REC"
indication will disappear and the datalogger function will be finished.
Manual datalogger (Set sampling time = 0 seconds)
a. Set sampling time to 0 seconds
Press the "REC Button (4-4) once. The LCD will show the text "REC", then press the "Logger Button" (4-
8) once, "REC" will flash once and the beeper will sound once. At the same time, the measuring data
along with the time information and the position no. will be saved to the memory circuit.
Note:
* For the 4-channel measurement, the lower right display area will show the position/location no.
(P1, P2... P99) and the T4 measurement value alternately.
* During execution of the manual datalogger function, use the "▲ Button" (4-5) or the "▼ Button"
(4-6) to set the measuring position (1 to 99, for example room 1 to room 99) to identify the
measurement location.
b. Finish the Datalogger
Press the "REC Button" (4-4) continuously for at least two seconds. The "REC" indication will disappear
and the datalogger will be finished.
Check time information
During normal measurement (no datalogger), when you press the "Time check Button" (4-
7) once, the lower LCD display will present the time information Year/Month, Date/Hour, Minute/Second.
Check sampling time information
During normal measurement (no datalogger), when you press the "Sampling Button" (4-8) once , the
lower LCD display will present the sampling time information in the second unit.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for PCE instruments PCE-T 390 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of PCE instruments PCE-T 390 in the language / languages: English as an attachment in your email.

The manual is 0,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of PCE instruments PCE-T 390

PCE instruments PCE-T 390 User Manual - German - 14 pages

PCE instruments PCE-T 390 User Manual - Dutch - 15 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info