DANGER
The device and packaging materials are not toys!
Children must not be allowed to play with plastic
bags, film and small parts! There is a risk of swal-
lowing and suffocation!
Before you connect the equipment to the mains supply, make
sure that the data on the rating plate are identical to the mains
data.
Prior to initial commissioning, remove the transport lid (A)
and fill the compressor pump housing with oil as described
in item 9.4.
Check the equipment for damage which may have occurred
in transit. Report any damage immediately to the transport
company which was used to deliver the compressor.
Install the compressor near the point of consumption.
Avoid long air lines and supply lines (extension cables).
Make sure that the intake air is dry and dustfree.
Do not install the compressor in a damp or wet room.
The compressor may only be used in suitable rooms (with
good ventilation and an ambient temperature from +5 °C
to 40 °C). There must be no dust, acids, vapours, explosive
gases or inflammable gases in the room.
The compressor is designed to be used in dry rooms. It is
prohibited to use the compressor in areas where work is con-
ducted with sprayed water.
The oil level in the compressor pump has to be checked be-
fore putting the equipment into operation.
9. Assembly and operation
m Attention!
You must fully assemble the appliance before us-
ing it for the first time!
You will require the following tools for assembly:
1x Open-end spanner 13 mm
1x Phillips screwdriver
(not included)
9.1 Fitting the wheels (fig. 4)
Fit the supplied wheels as shown.
9.2 Fitting the supporting feet (fig. 5)
Fit the supplied supporting feet as shown.
9.3 Fitting the air filter (fig. 6, 7)
Remove the transport lid (B) and screw the air filter (15) to
the equipment.
9.4 Changing the transportation lid (A) (fig. 8, 9)
Remove the transport lid (A) of the oil filling opening (20).
Fill the included compressor oil into the compressor pump
housing and insert the supplied oil sealing plug (16) into the
oil filling opening (20).
9.5 Mains connection
The compressor is equipped with a mains cable with shock-
proof plug. This can be connected to any 220 - 240 V∼
50Hz shock-proof socket.
Before you use the machine, make sure that the mains volt-
age is the same as the operating voltage and the machine
power on the rating plate.
Long supply cables, extensions, cable reels, etc. cause a
drop in voltage and can impede motor start-up.
At low temperatures below +5°C, sluggishness may make
starting difficult or impossible.
9.6 ON/OFF switch (fig. 2)
Pull the ON/OFF switch (17) upwards to switch on the com-
pressor. To switch off the compressor, press the ON/OFF
switch down.
9.7 Setting the pressure (fig. 1, 3)
Use the pressure regulator (5) to set the pressure on the pres-
sure gauge (4).
The set pressure can be drawn from the quick lock coupling
(3).
The vessel pressure can be read off the pressure gauge (6).
The vessel pressure is drawn from the quick-lock coupling
(7).
9.8 Setting the pressure switch (fig. 1)
The pressure switch (2) is set at the factory.
Cut-in pressure approx. 8 bar
Cut-out pressure approx. 10 bar.
9.9 Fitting the compressed air hose (fig. 1, 3)
Connect the nipple (H) on the compressed air hose (14) to
one of the quick-release couplings (3, 7). Then attach the
compressed air tool to the quick-release coupling (I) on the
compressed air hose (14).
9.10 Overload switch (fig. 13)
The motor is fitted with an overload switch (24). If the compres-
sor overloads, the overload switch switches off the equipment
automatically to protect the compressor from overheating. If
the overload switch triggers, switch off the compressor using
the ON/ OFF switch (17) and wait until the compressor cools
down. Then press the overload switch (24) and restart the com-
pressor.
10. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The cus-
tomer‘s mains connection as well as the extension
cable used must also comply with these regula-
tions.
10.1 Important information
In the event of an overloading the motor will switch itself off. Af-
ter a cool-down period (time varies) the motor can be switched
back on again.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside PKO 24 A1 - IAN 339151 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside PKO 24 A1 - IAN 339151 in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 6.05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info