24
GB IE
The device must only be con-
nected to a mains socket via
a RCD (Residual Current De-
vice) with a rated leakage cur-
rent of not more than 30mA.
Fuse: at least 13ampere.
Before each use, check the
equipment, cable and plug
for damage.
If the power cable for this
equipment is damaged, it
must be replaced by the
manufacturer, a customer ser-
vice agent of the same or a
similarly qualied person in
order to prevent hazards.
Do not pull the plug from the
socket by the cable. Protect
the cable from heat, oil and
sharp edges.
Do not carry or x the equip-
ment by the cable.
Unsuitable extension cables
can be dangerous. If an ex-
tension cable is used it must
be suitable for outdoor use,
and be routed above the
ground. We recommend us-
ing a cable drum that holds
the socket at least 60mm
above the ground.
Check the cable for damage.
Before any work on the
equipment, during work
breaks and in the case of
non-use, remove the plug
from the socket.
The cross-section of the pow-
er supply cable must not be
less than 2x2,5mm².
Wear sturdy footwear to pro-
tect against electric shock.
To protect against electric
shock, operate the equipment
only in an upright position.
Always shut off the power
switch when leaving the ma-
chine unattended.
Start-up
In keeping with current regulations a
pressure cleaner must never be oper-
ated off the drinking water mains
supply without a controllable back-
ow preventer. A suitable backow
preventer in conformity with
EN 12729 type BA must be used.
Water that has passed through a backow
preventer is classied as undrinkable.
A backow preventer is available in spe-
cialist shops.
A system separator (check valve) prevents
the backow of water and detergent into
the drinking water pipeline.
Use a commercially available 1/2”
garden hose, at least 5m long, for wa-
ter supply.
Do not exceed a length of 30m.
Use the device on a domestic water
connection with an output of at least
450l/h.
Setting up
1. Pull the curved handle (2) up as far as
it will go.
2. Connect the high-pressure tting (jet
gun) (29) to the jet gun (14). Ensure
that the hose runs to the front, so as not
to impede the handle (2).
3. Connect the feed hose to the water
supply and allow water to escape from
the other end of the feed hose with no
bubbles, in order to expel the air from
the feed hose. Switch off the water tap.
4. Connect the feed hose with the help of
the quick connector for garden hose
adapter (22) with the water connection
24


Need help? Post your question in this forum.

Forumrules
1

Forum

parkside-phd-170-b2---ian-346400

Reset search

  • Parkside 170 Phd b2 ait 1= 3 adet Yag keçesi 2= 3 Adet Su Contasi 3= 3 Adet Sibop ihtiyacim var. Acil temin etmem gerek. Submitted on 11-3-2022 at 12:58

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside PHD 170 B2 - IAN 346400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside PHD 170 B2 - IAN 346400 in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 2,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Parkside PHD 170 B2 - IAN 346400

Parkside PHD 170 B2 - IAN 346400 User Manual - German - 22 pages

Parkside PHD 170 B2 - IAN 346400 User Manual - Dutch - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info