5
To select the display unit,
1. Press the indoor temperature window.
2.
Press [UNIT] repeatedly for the desired setting. The selected
unit will apply to all temperature displays in this window.
NOTE The unit of all temperature related display will be
changed simultaneously.
To display the dew point temperature, press the indoor
temperature window until the “DEW” indicator is displayed.
To display maximum, minimum temperatures,
1. Press the indoor temperature window or repeatedly
until the "DEW" icon appears.
2. Press [MEMORY] repeatedly for the desired record.
The time and date of the record will also be displayed
alternatively with the “STAMP” icon in the clock window.
The display will automatically return to the current
temperature or dew temperature whatever is previously
displayed if the unit is left untouched for about one minute.
To clear the memory,
1. Press the indoor temperature window or repeatedly
until the "DEW" icon appears.
2. Press and hold [MEMORY] till the key tone is heard.
3. Press [MEMORY] to check the memory is clear.
INDOOR HUMIDITY
The current indoor relative humidity, taken by the indoor
baro-thermo-hygrometer, is displayed on the indoor
hygrometer window.
To display the maximum, minimum and current humidity,
1. Press the indoor humidity window.
2. Press [MEMORY] repeatedly for the desired record.
The time and date of the record will also be displayed
alternatively with the “STAMP” icon in the clock window.
To clear the memory,
1. Press the indoor humidity window.
2. Press and hold [MEMORY] until the key tone is heard.
3. Press [MEMORY] to check the memory is clear.
OUTDOOR AND CHANNEL TEMPERATURES
The temperature readings taken by the outdoor thermo-
hygrometer and separate thermo or thermo-hygro sensors
are displayed on the outdoor and channel temperature
window.
As this window can display up to four different sets of data,
specify the instrument or channel you want to read.
To do so,
1. Press the outdoor/channel temperature window.
2. Press [CHANNEL] to go from the outdoor reading
taken by the outdoor thermo-hygrometer to those taken
by individual sensors (Channel 1, 2 or 3).
The outdoor thermo-hygrometer is also capable of
detecting the dew point temperature as well as the wind
chill reading. To display such information, press the window
repeatedly.
The temperatures can be displayed in degrees Centigrade
(˚C) or Fahrenheit (˚F).
To select the display unit,
1. Press the outdoor/channel temperature window.
2. Press [UNIT] repeatedly for the desired setting. The
selected unit will apply to all temperature displays in this
window.
NOTE The unit of all temperature related displays will
change simultaneously.
To display the maximum, minimum temperatures,
1. Press the outdoor/channel temperature window or
repeatedly until the "DEW" icon appears.
2. Press [CHANNEL] for the outdoor thermo-hygrometer
or the desired channel.
3. Press [MEMORY] repeatedly for the desired record.
The time and date of the record will also be displayed
alternatively with the “STAMP” icon in the clock window.
To display the dew point temperature for a channel, press
the window again when the channel temperature is located.
To clear the memory,
1. Press the outdoor/channel temperature window or
repeatedly until the "DEW" icon appears.
2. Press [CHANNEL] for the outdoor thermo-hygrometer
or the desired channel.
3. Press and hold [MEMORY] until the key tone is heard.
4. Press [MEMORY] to check the memory is clear.
OUTDOOR AND CHANNEL HUMIDITY
The relative humidity readings taken by the outdoor thermo-
hygrometer and separate thermo-hygro sensors are
displayed on the outdoor/channel humidity window.
As this window can display up to four different sets of data,
specify the instrument or channel you want to read.
To do so,
1. Press the outdoor/channel humidity window.
2. Press [CHANNEL] to go from the outdoor reading
taken by the thermo-hygrometer to those taken by
individual sensors (Channel 1, 2 or 3).
To display the maximum, minimum and current
humidity,
1. Press the outdoor/channel humidity window.
2. Press [CHANNEL] for the outdoor thermo-hygrometer
or the desired channel.
3. Press [MEMORY] repeatedly for the desired record.
The time and date of the record will also be displayed
alternatively with the “STAMP” icon in the clock window.
To clear the memory,
1. Press the outdoor/channel humidity window.
2. Press [CHANNEL] for the outdoor thermo-hygrometer
or the desired channel.
3. Press and hold [MEMORY] until the key tone is heard.
4. Press [MEMORY] to check the memory is clear.
WMR968_EN_output 12/17/2004, 15:055
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific WMR968 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific WMR968 in the language / languages: English as an attachment in your email.

The manual is 1.6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info