796937
7
Zoom out
Zoom in
Previous page
1/25
Next page
EN
7
DISCONNECTED SIGNALS
If without obvious reason the display for the main unit
goes blank or “ ” is displayed, press and hold
[CHANNEL] to enforce an immediate search.
If that fails, check:
-All weather instruments are still in place.
-The batteries of the main unit and individual weather
instruments are still good. Replace them if necessary.
Press and hold [CHANNEL] to enforce an immediate
search afterwards.
-
T
he transmission is within range and path is cleared of
obstacles and interference. Shorten the distance if
necessary.
Then press and hold [CHANNEL] again. The main unit will
start searching for all previously locked weather
instruments.
If you want to add a new sensor, press the [RESET]
button on the new sensor and then press [CHANNEL] to
enforce the main unit to search.
NOTE 1. Do not reset the sensors after the main unit has
locked those sensors, otherwise the main unit
will no longer receive the signal from those
sensors.
2. If you have disconnected signals, you cannot
clear the memory.
THE RESET BUTTON
This button is only used when the system is operating in
an unfavorable way or malfunctioning. Use a blunt stylus
to hold down the button. The main unit will return to all
default settings and start searching for signals again.
Before resetting the main unit, you should do the same
for all weather instruments to ensure correct transmission
and reception of signals. Then press [RESET] on the
main unit.
MAINTENANCE
When handled properly, this unit is engineered to give you
years of satisfactory service. Here are a few product care
instructions:
1.
Do not immerse the unit in water. If the unit comes in contact
with water, dry it immediately with a soft lint-free cloth.
2. Do not clean the unit with abrasive or corrosive materials
Abrasive cleaning agents may scratch the plastic parts
and corrode the electronic circuit.
3. Do not subject the unit to excessive: force, shock, dust,
temperature, or humidity. Such treatment may result in
malfunction, a shorter electronic life span, damaged
batteries, or distorted parts.
4. Do not tamper with the unit’s internal components. Doing
so will terminate the unit’s warranty and may cause
damage. The unit contains no user-serviceable parts.
5.
Only use new batteries as specified in this instruction
manual. Do not mix new and old batteries as the old
batteries may leak.
6. Read this instruction manual thoroughly before operating
the unit.
SPECIFICATIONS
Temperature
Proposed Operating Range
:Indoor ..... 23˚F to 122˚F
(-5˚C to 50˚C)
:Outoor ..... -4˚F to 140˚F
(-20˚C to 60˚C)
Resolution :0.2˚F (0.1˚C)
(indoor and outdoor)
Relative Humidity
Measuring Range :2 to 98% RH
(indoor and outdoor)
Resolution :1% RH
(indoor and outdoor)
Dew Point Temperature
Measuring Range :Indoor ..... 32˚F to 120.2˚F
(0˚C to 49˚C )
:Outoor ..... 14˚F to 140˚F
(-10˚C to 60˚C)
Resolution :2˚F (1˚C)
(indoor and outdoor)
Barometric Pressure / Trend
Measuring Range :795 to 1050 mb
(23.48 to 31.01 inHg)
Resolution :1 mb (0.03 inHg)
Wind Speed
Measuring Range : 0 to 125.3 mph (0 to 56 m/s)
Resolution :0.4 mph (0.2 m/s) (typical)
Wind Direction
Measuring Range :0˚ to 359˚ (Degrees)
Digital Resolution :1˚ (typical)
Graphical Resolution :10˚
Wind Chill Temperature
Measuring Range :
-61.6˚F to 140˚F (-52˚C to 60˚C)
Resolution :2˚F (1˚C)
Rainfall
Daily and Cumulative :0 to 393.7 in (0 to 9999 mm)
Measuring Range
Rainfall Rate :
0 to 39.37 in/hr (0 to 999 mm/hr)
Measuring Range
Daily and Cumulative : 0.04 in (1 mm)
Resolution
Rainfall Rate Resolution :1mm/hr (0.04 m/h) typical
WMR968 :
Weight :18 oz (505 g)
Dimension :8 (L) x 5.5 (W) x 1.5 (H) in
(204 x 139 x 39 mm)
Power :12V AC / DV adapter
Power backup :4 x UM3 - “AA” size alkaline
batteries
WMR968_EN_output 12/17/2004, 15:057
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific WMR968 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific WMR968 in the language / languages: English as an attachment in your email.

The manual is 1.6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info