492720
18
Zoom out
Zoom in
Previous page
1/35
Next page
© Calibre UK Limited Issue 2.00 30 March 2012, W: www.calibreuk.com
T:+44 1274 394125 F: +44 1274 730960 E: techsupport@calibreuk..com 14
3.3.
Main Menu
The main menu lists the input channel select item, 6 sub menus, and a menu item for automatic setup
of VGA modes. The 6 sub menus are Output, Color, Geometry, PiP (HQView-500S) or Multiple Unit
(HQView-510 and 520/530), Enhancement and System.
On each menu page an Exit menu item is available to leave the menu or submenu. HQView-500S/510
and 520 also allow to leave a menu or submenu by pressing the up/down key simultaneously. HQView-
530 has a separate back key for this purpose.
Some adjustments are not applicable to all signal types or operating modes, in which case those non-
applicable functions will be ghosted and are not accessible via the menus.
All menus have a top status line and a bottom line indicating the firmware revision number. In the
status line the currently selected input channel is indicated and the detected mode is identified. The
firmware revision number displays the revision number of the bootloader behind BL, the revision
number of the firmware behind FW and whether it is a 500S, 510, 520 or 530 type HQView unit.
Navigating the menu system or changing values is done with the up and down keys in the case of
HQView-500S, 510 and 520 or a jog wheel in the case of HQView-530. In the following sections the
set-up method using the up and down keys is described.
To set up your HQView-5xx it is recommended that you follow this procedure:
Choose the correct output mode and parameters to suit your screen or projector.
Select the correct input signal.
Set the input levels and features appropriately to optimize the appearance of your image.
Set any other parameters to suit your application.
Note: All Input parameters are specific to your chosen input channel and input signal type, they are not
global to the unit. All Output parameters are global
3.4.
Input
The list of available inputs can be scrolled through using the Up and Down keys. The new input is not
selected until the Menu key is pressed. The list of inputs are: CVBS 1, CVBS 2, S-Video, Component,
VGA, 3G-SDI, DVI, HDMI and Test Pattern.
Test patterns can be generated by HQView-5xx without needing an input connected. When Test
Pattern is selected as the input, the required test pattern can be chosen with the menu navigation
up/down keys when the OSD menu is off.
3.5. Output
This menu contains adjustments associated with setting up outputs from the unit. The items are
organized in three sub menus, Display Type, Gamma/Color/Crush and Output Config. Use the up and
down keys to scroll to the required item and press the Menu key.
3.5.1. Display Type
Settings: LCD/Plasma, Projector
The Display Type setting defaults to Projector. Select Projector if you drive a projector and need the
warp function and edge blend capability. Set to LCD/Plasma if you do not need warp (including
Location). Multiple unit configurations with auto zoom are available, but without edge blend. The real
value of this mode is that the Flicker Filter becomes available. Note: For HQView-500S leave the
setting to Projector mode, since there is no difference to LCD/Plasma mode.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Optoma HQView-500 Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Optoma HQView-500 Series in the language / languages: English as an attachment in your email.

The manual is 1,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info