Installation instructions
for the specialist company
LEVANA 2.0 6 kW
LEVANA 2.0 8 kW
LEVANA AQUA 2.0
ARINA 2.0
INARA 2.0
EN
2.10 Checking the installation and function
Check the fully completed installation (visual inspection)!
Switch the pellet replace on and check all of the functions, and
check the chimney ue for leaks! Carry out initial commissioning!
2.11 Initial commissioning by the specialist company
Please ensure that no objects made from ammable materials
are located or placed in the radiation range of the replace (min-
imum distance 800 mm, measured from the viewing window in
the combustion chamber door)!
Before heating for the rst time, check that all accessories have
been removed from the ash pan and combustion chamber! To do
this, release the ash pan lock, which is located behind the inspec-
tion door, and pull the ash pan out to the front! The combustion
chamber door lock is located underneath the combustion cham-
ber door.
Remove the protective lm from the touch control panel!
Convection air openings may not be covered!
The precautions for the combustion air supply may not be mod-
ied. In particular, care must be taken to ensure that the nec-
essary combustion air lines are open during operation of the
replace!
Plug the white and blue connector supplied into the socket on
the rear of the appliance. If the pellet replace should be operated
with accessories (e.g. room thermostat)! Connect the connection
cables to the connector rst!
Note: the connector must be plugged in even without acces-
sories, otherwise the pellet replace is not ready for operation.
Plug the shockproof plug into a 230 V/50 Hz shockproof socket.
Fill the pellet reservoir with pellets (see chap. 3.2)!
During initial commissioning, or if the pellet duct is empty, or
if the reservoir runs empty, a handful of pellets must be poured
into the burner trough towards the igniter. Otherwise, only the
pellet duct will be lled within the lling period in the start phase
and only an insucient 2-5 pellets will fall into the burner trough.
Fig. 2.41 Pour pellets in manually if the pellet duct is empty
Set the master switch to “I” (back right of the appliance)!
ū The touch control panel display is activated automatically.
Note: the smell which may occur as a result of curing of the
protective coating will disappear once the pellet replace has
been burning with good room ventilation for several hours.
Attention! Property damage! The pellet fireplace is coated
with a high-quality temperature-resistant coating which only
reaches its final strength after being heated for the first time.
You therefore should not place anything on the tiled pellet
fireplace or touch the surfaces as this may damage the
coating.
2.12 Handover of the system to the user
After installation, instruct the user of the system with regard to:
ū Use,
ū Operation,
ū Functioning,
ū Care and cleaning (user),
ū Necessary annual maintenance (specialist company)!
In particular, instruct the user of the system in the risks associated
with the pellet replace, as well as in the safety information and
safety precautions!
Fill out the handover certicate (blank form attached)!
Hand the product/the system over to the user together with this
manual and all other documents!
Commissioning certicate
The proper installation, commissioning and handover of the pellet
replace is documented by the commissioning certicate (sepa-
rate document). Instruction of the system user by the specialist
company, in particular in the risks associated with the pellet re-
place and in the safety information and safety precautions is also
certied by the specialist company and user’s signatures.
2.13 Disassembly and disposal
The applicable international, national and region-specic laws and
regulations at the time of disposal of the pellet replace must be
observed.
Take care to ensure that the recyclability of materials, and the pos-
sibility of disassembly and separation of materials and assem-
blies is taken into consideration as well as the environmental and
health risks of recycling and disposal. Material groups such as
plastics and metals of dierent types should be sorted before be-
ing sent for recycling or disposal!
The disposal and recycling of electrical and electronic compo-
nents must be done in accordance with the appropriate laws and
country-specic regulations!
We reserve the right to make technical changes
73
78-4643-2481_R6_LEVANA 2.0_ARINA 2.0_INARA 2.0_DE-EN-FR.indd 7378-4643-2481_R6_LEVANA 2.0_ARINA 2.0_INARA 2.0_DE-EN-FR.indd 73 11.04.2023 14:41:5211.04.2023 14:41:52
73


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Olsberg ARINA 2.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Olsberg ARINA 2.0 in the language / languages: English, German, French as an attachment in your email.

The manual is 34.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info