551851
20
Zoom out
Zoom in
Previous page
1/62
Next page
20
OCS OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-5272-r01 (9/28/11)
Log Data 1, information includes (Fig. 34):
> Log Mode (book) icon.
> Max Depth with MAX and FT (or M) icons.
> Graphic DSAT (or Z+), the Algorithm selected.
> Graphic EDT with Dive Time (hr:min).
> Graphic SURF and pre dive SI (hr:min), 0:00 if Dive # 1, 9: - - if > 9:59, with Time (clock) icon.
> Temperature (minimum that dive) with ° icon and graphic F (or C).
> TLBG with the max segment flashing, others fixed up to end of dive accumulation. All segments flashing if a Violation.
Blank if GAUG.
> VARI, max Ascent Rate sustained for 4 sec.
> Nx icon, if Nitrox.
• S (< 2 sec) - to access the dive's Log Data 2 screen if Nitrox, or revert to the Preview screen if Air or a Violation.
• L (press) - to activate Backlight.
Log Data 2 (Nitrox only), information includes (Fig. 35):
> Log Mode (book) icon.
> Graphic GAS 1 (or 2 or 3), in use when dive ended.
> Graphic FO2 with FO2 Set Point (or graphic Air) for Gas in used when dive ended.
> Graphic PO2 with value of Max PO2 achieved.
> Nx icon.
> O2BG with O2 icon, accumulated when dive ended.
• S (< 2 sec) - to revert to the Preview screen.
• L (press) - to activate Backlight.
SET F (FO2)
Each Gas has an individual FO2 and an associated PO2 Alarm setting.
Default settings are FO2 Air with no PO2 value for Gas 1, and Off for Gas 2 & 3. Settings revert to the defaults when 24 hours
elapse without conducting a dive.
When FO2 is set for Air -
> calculations are the same as when FO2 is set for 21%.
> it remains set for Air until set for Nitrox (21 to 100%).
> O2 data (such as PO2, O2%) will not be displayed at any time during the dive, on the surface, or in Plan mode.
> MODs (Max Operating Depths) will not be displayed on the FO2 set screen.
> internally, it will keep track of O2 data for use if FO2 is subsequently set for Nitrox for repetitive dives.
When FO2 is set for Nitrox -
> The Air option will not be displayed as an FO2 setting until 24 hours elapse after the last dive.
When FO2 is set for OFF (Gas 2, 3) -
> That Gas will not be available in the Gas Switch routine during dives (no Switch To - screen).
FO2 50% Default -
> When the Default is set OFF, FO2 values will remain set at their last settings saved until 24 hours elapse without conducting
a dive.
> When the Default is set ON and FO2 is set for Nitrox, 10 minutes on the surface after that dive the FO2 will be displayed
as 50 and further dives will be calculated based on 50% O2 for oxygen calculations and 21% O2 for Nitrogen calculations
(79% Nitrogen), unless FO2 is set before the dive.
> FO2 will continue to reset to the Default after repetitive dives until 24 hours elapse with no dive, or the Default is set OFF.
SET F (FO2) MENU
Menu selections (Fig. 36) >> Gas 1 >> Gas 2 >> Gas 3 >> FO2 Default.
• S (< 2 sec) - to access Set F Menu while the selection Arrow icon ( > ) is next to Set F on the NORM Menu.
• A (< 2 sec) - to step down (forward) through selections.
• M (< 2 sec) - to step up (back) through selections.
• S (< 2 sec) - to access selection indicated by Arrow icon ( > ).
The last setting saved, or the default, is displayed next to each Menu item.
SET GAS 1 FO2/PO2, information includes:
> Max Depth allowed for the PO2 Alarm setting displayed, blank when Air.
> Graphic GAS1.
> Graphic FO2 with setting Air or 21 to 100 flashing (Fig. 37A/B).
> Graphic PO2 with Alarm value set.
> Nx icon (if Nitrox, numerical values), blank if Air.
A (press/hold), while the FO2 digits are flashing - to scroll upward through the Set Points from Air to 21 through 100 in 1%
increments, at a rate of 8 per second.
>> The scroll will stop when the button is released, or momentarily at 32, then 50, then 80 (%).
Fig. 34 - LOG DATA 1
Fig. 35 - LOG DATA 2










Fig. 37A - SET GAS 1 FO2
(default)
Fig. 37B - SET GAS 1 FO2
(Nitrox)
Fig. 38 - SET GAS 1 PO2
ALARM
Fig. 36 - SET F MENU
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic OCS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic OCS in the language / languages: English as an attachment in your email.

The manual is 9,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic OCS

Oceanic OCS Quick start guide - English - 2 pages

Oceanic OCS Quick start guide - German - 2 pages

Oceanic OCS User Manual - German - 62 pages

Oceanic OCS Quick start guide - French - 2 pages

Oceanic OCS User Manual - French - 62 pages

Oceanic OCS Quick start guide - Italian - 2 pages

Oceanic OCS User Manual - Italian - 62 pages

Oceanic OCS Quick start guide - Spanish - 2 pages

Oceanic OCS User Manual - Spanish - 62 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info