551838
21
Zoom out
Zoom in
Previous page
1/68
Next page
21
OC1 OPERATING MANUAL
© 2002 Design, 2009 Doc. No. 12-2761-r04 (9/6/11)
Set FO2 Gas 3, information includes (Fig. 38):
> Max Depth with MAX and FT (or M) icons, allowed for PO2 Alarm Set, blank if Air
> Graphic GAS2
> Graphic FO2 with FO2 Set Point value, flashing
> Graphic PO2 with alarm value set
> Nx icon, blank if Air
• A (hold) to scroll upward through Set Points at a rate of 8 per second from Air** to 21 through 100 (%) in increments of
1%.
> The scroll will start at the FO2 Gas 2 Set Point** and stop when A is released, or pause at 50 then again at 80% if A is
held depressed.
> Depress A, or keep it depressed, to resume the scroll up through 100, then stop at the Gas 2 Set Point.
• A (< 2 sec) to step upward through Set Points one at a time
• M (< 2 sec) to step back through Set Points one at a time
• S (< 2 sec) to save the setting and revert to the Set F Menu
**Gas 3 cannot be set at a value less that set for Gas 2.
Set FO2 Default, information includes (Fig. 39):
> Graphics DEFAULT and 50
> Set Point graphics ON and OFF; Arrow ( > ) icon next to the one previously saved flashing
> Nx icon, blank if Air
• A (< 2 sec) to toggle Set Points
• S (< 2 sec) to save the setting and revert to the Set F Menu
Turning the FO2 Default feature On controls FO2 Nitrox settings regardless of Set Points selected for Gases 1, 2, or 3.
Refer to page 29 for an overview of the 50% Default feature.
SET A (ALARMS) MENU
S (< 2 sec) - to access Set A Menu while the selection Arrow icon ( > ) is next to Set A on the NORM (or GAUG) Menu
A (< 2 sec) - to step down (forward) through selections
M (< 2 sec) - to step up (back) through selections
S (< 2 sec) - to access selection indicated by Arrow icon ( > )
Refer to page 9 for additional information relating to Alarms.
Set Audible Alarm, information includes (Fig. 40):
> Graphic AUDIBLE
> Set Point graphics ON and OFF; Arrow ( > ) icon next to the one previously saved flashing
• A (< 2 sec) to toggle Set Points
• S (< 2 sec) to save the setting and revert to the Set A Menu
Set Depth Alarm, information includes (Fig. 41):
> Graphic DEPTH AL
> Graphic OFF flashing, or Depth value flashing with MAX and FT (or M) icons
• A (hold) to scroll upward through Set Points at a rate of 8 per second from 30 to 330 FT (10 to 100 M) in increments of 10
FT (1 M)
• A (< 2 sec) to step upward through Set Points one at a time
• M (< 2 sec) to step back through Set Points one at a time
• S (< 2 sec) to save the setting and revert to the Set A Menu
There is a separate alarm associated with exceeding the MOD (max operating depth) which is a violation described later.
FREE mode has separate Depth Alarms that are not affected by this setting.
Set EDT Alarm, information includes (Fig. 42):
> Graphic EDT AL with MAX icon
> Elapsed Dive Time value (hr:min) flashing with MAX and Time (clock) icons
• A (hold) to scroll upward through Set Points at a rate of 8 per second from 0:10 to 3:00 (hr:min) in increments of :05 (:min)
• A (< 2 sec) to step upward through Set Points one at a time
• M (< 2 sec) to step back through Set Points one at a time
• S (< 2 sec) to save the setting and revert to the Set A Menu
FREE Mode has a separate EDT Alarm.
Fig. 38 - SET FO2 GAS 3
Fig. 39 - SET FO2 DEFAULT










** NORM only
Fig. 40 - SET AUDIBLE AL
Fig. 41 - SET DEPTH AL
Fig. 42 - SET EDT AL
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic OC1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic OC1 in the language / languages: English as an attachment in your email.

The manual is 8,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic OC1

Oceanic OC1 User Manual - English - 180 pages

Oceanic OC1 Additional guide - German - 2 pages

Oceanic OC1 Quick start guide - German - 2 pages

Oceanic OC1 User Manual - German - 68 pages

Oceanic OC1 Additional guide - French - 2 pages

Oceanic OC1 Quick start guide - French - 2 pages

Oceanic OC1 User Manual - French - 68 pages

Oceanic OC1 Additional guide - Italian - 2 pages

Oceanic OC1 User Manual - Italian - 68 pages

Oceanic OC1 User Manual - Turkish - 180 pages

Oceanic OC1 User Manual - Spanish - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info