550349
22
Zoom out
Zoom in
Previous page
1/56
Next page
22
ATOM 3.0 OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-5216-r02 (9/6/11)
Set SS (NORM Safety Stop), information includes (Fig. 62):
> Graphics SEt and SAFE St with Stop arrow/bar icons.
> Set Point graphic ON (or OFF) flashing.
- or -
> Graphic SEt with Stop arrow/bar icons.
> Set Point graphic ON TMR flashing.
• A (< 2 sec) - to step forward through the Set Points (SAFE St OFF, SAFE St ON, TMR ON).
• S (< 2 sec) - to save the setting.
• S (2 sec), if no change - to revert to Set DS.
>> If SS OFF (Fig. 60A, page 58) or TMR ON (Fig. 60B) is selected, operation accesses Set Algorithm.
>> If SS ON is selected, Stop Depth and Time is displayed with min and sec icons, Time digits flashing (Fig. 60C).
• A or M (< 2 sec) - to toggle Stop Time Set Points between 3:00 and 5:00 (min:sec).
• S (< 2 sec) - to save the Time setting and flash Depth digits.
• A (< 2 sec) - to step up through Depth Set Points of 10, 15, and 20 FT (or 3, 4, 5, and 6 M).
• M (< 2 sec) - to step back through Set Points.
• S (< 2 sec) - to save the setting and access Set Algorithm.
Set Algorithm (NORM), information includes (Fig. 63):
> Graphics SEt and ALGO.
> Set Point graphic PZ+ (or DSAT) flashing.
• A or M (< 2 sec) - to toggle between DSAT and PZ+.
• S (< 2 sec) - to save the setting and access Set CF.
• S (2 sec), if no change - to revert to Set SS.
This feature allows selection of the Algorithm to be used for nitrogen and oxygen calculations for Plan and Dive allowed time values.
The setting locks in for 24 hours after NORM dives.
Set CF (Conservative Factor, NORM), information includes (Fig. 64):
> Graphics SEt and CF with icon.
> Set Point graphic ON (or OFF) flashing.
• A or M (< 2 sec) - to toggle between ON and OFF.
• S (< 2 sec) - to save the setting and access Set Glo.
• S (2 sec), if no change - to revert to Set Algorithm.
When CF is set On, NDLs are reduced to values equivalent to those that would be available at the next higher 3000 foot (915 meter) Altitude.
Refer to tables in back of manual.
Set Glo (Backlight Duration), information includes (Fig. 65):
> Graphics SEt and GLO.
> Time Set Point value flashing with sec icon.
• A (< 2 sec) - to step upward through Set Points of 0, 5, and 10 (sec) one at a time.
• M (< 2 sec) - to step back through Set Points one at a time.
• S (< 2 sec) - to save the setting and access Set SR.
• S (2 sec), if no change - to revert to Set CF.
Backlight Duration is the time the backlight will remain On after the L button is released (0 = no additional time).
Set SR (Sampling Rate), information includes (Fig. 66):
> Graphics SEt and SR.
> Time Set Point value flashing with sec icon.
• A (< 2 sec) - to step upward through Set Points of 2, 15, 30, and 60 (sec) one at a time.
• M (< 2 sec) - to step back through Set Points one at a time.
• S (< 2 sec) - to save the setting and access Set TMT 1.
• S (2 sec), if no change - to revert to Set Glo.
Sampling Rate is the frequency at which data is sampled and stored for download to the OceanLog PC Interface program.
A
Fig. 62 - SET SS
B
C
Fig. 63 - SET ALGORITHM
Fig. 64 - SET CF
Fig. 65 - SET GLO
Fig. 66 - SET SR
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic Atom 3.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic Atom 3.0 in the language / languages: English as an attachment in your email.

The manual is 12,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic Atom 3.0

Oceanic Atom 3.0 Quick start guide - English - 2 pages

Oceanic Atom 3.0 User Manual - German - 56 pages

Oceanic Atom 3.0 Quick start guide - French - 2 pages

Oceanic Atom 3.0 User Manual - French - 56 pages

Oceanic Atom 3.0 Quick start guide - Italian - 2 pages

Oceanic Atom 3.0 User Manual - Italian - 56 pages

Oceanic Atom 3.0 User Manual - Spanish - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info