ATOM 3.0 OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-5216-r02 (9/6/11)
Set End Alarm (TMT 1, 2, 3) information includes (Fig. 56):
> Graphics SEt and END AL with all Tank icons (1, 2, 3).
> Set Point graphic OFF (or Pressure value) flashing, with PSI (or BAR) icon.
• A (hold) - to scroll upward through Set Points (8/sec) from 300 to 1500 PSI (20 to 105 BAR) in 100 PSI (5 BAR) increments.
• A (< 2 sec) - to step upward through Set Points.
• M (< 2 sec) - to step back through Set Points.
• S (< 2 sec) - to save the setting and access Set PO2 Alarm.
• S (2 sec), if no change - to revert to Set Turn Alarm.
Set PO2 Alarm (NORM), information includes (Fig. 57):
> Graphic SEt and AL.
> PO2 value (ATA) flashing with icon.
• A (< 2 sec) - to step upward through Set Points from 1.20 to 1.60.
• M (< 2 sec) - to step back through Set Points.
• S (< 2 sec) - to save the setting and revert to Set A Lead-in.
• S (2 sec), if no change - to revert to Set End Alarm.
SET U GROUP (UTILITIES)
Selections >> Wet > Units > DS* > SS* > Algo* > CF* > Glo > SR > TMT 1 > TMT 2 > TMT 3.
*Items apply to NORM only.
> Set Points remain as set until changed.
Set U Lead-in, information includes (Fig. 58):
> Graphics Goto and SET U.
• A (< 2 sec) - to step forward to Select DIVE OP mode.
• M (< 2 sec) - to step back to SET A.
• S (< 2 sec) - to access Set Wet.
Set Wet Activation, information includes (Fig. 59):
> Graphics SEt and WET.
> Set Point graphic ON (or OFF) flashing.
• A or M (< 2 sec) - to toggle between ON and OFF.
• S (< 2 sec) - to save the setting and access Set Units.
• S (2 sec), if no change - to revert to SET U.
Set Units, information includes (Fig. 60):
> Graphic SEt and UNIT.
> Set Point icons FT and PSI (or M and BAR) flashing.
• A or M (< 2 sec) - to toggle between FT/PSI and M/BAR.
• S (< 2 sec) - to save the setting and access Set DS if NORM, or Set Glo if GAUG.
• S (2 sec), if no change - to revert to Set Wet.
Set DS (NORM Deep Stop), information includes (Fig. 61):
> Graphic SEt and DEEP St with Stop arrow/bar icons.
> Set Point graphic ON (or OFF) flashing.
• A or M (< 2 sec) - to toggle between ON and OFF.
• S (< 2 sec) - to save the setting and access Set SS.
• S (2 sec), if no change - to revert to Set Units.
When set On, the Deep Stop feature activates when descent is made to a depth deeper than 80 FT (24 M) during No Deco.
A Stop Depth is calculated to be 1/2 the Max Depth achieved, then upon ascent to within 10 FT (3 M) below that depth, the Deep Stop screen is
displayed in place of the No Deco Main.
Fig. 56 - SET END AL
(applies to TMT in use)
Fig. 57 - SET PO2 AL
Fig. 58 - SET U LEAD-IN
Fig. 59 - SET WET
ACTIVATION
Fig. 60 - SET UNITS
Fig. 61 - SET DS
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic Atom 3.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic Atom 3.0 in the language / languages: English as an attachment in your email.

The manual is 12,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic Atom 3.0

Oceanic Atom 3.0 Quick start guide - English - 2 pages

Oceanic Atom 3.0 User Manual - German - 56 pages

Oceanic Atom 3.0 Quick start guide - French - 2 pages

Oceanic Atom 3.0 User Manual - French - 56 pages

Oceanic Atom 3.0 Quick start guide - Italian - 2 pages

Oceanic Atom 3.0 User Manual - Italian - 56 pages

Oceanic Atom 3.0 User Manual - Spanish - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info