550349
20
Zoom out
Zoom in
Previous page
1/56
Next page
20
ATOM 3.0 OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-5216-r02 (9/6/11)
SET A GROUP (ALARMS), NORM/GAUG
Selections >> Aud > Depth > EDT > Turn > End > TLBG* > DTR* > PO2*
*Items apply to NORM only.
> Set Points remain as set until changed.
Set A Lead-in, information includes (Fig. 49):
> Graphics Goto and SET A.
• A (< 2 sec) - to step forward to SET U.
• M (< 2 sec) - to step back to SET F.
• S (< 2 sec) - to access Set Audible Alarm.
Set Audible Alarm, information includes (Fig. 50):
> Graphics SEt and AUD AL.
> Set Point graphic ON (or OFF) flashing.
• A or M (< 2 sec) - to toggle between ON and OFF.
• S (< 2 sec) - to save the setting and access Set Depth Alarm.
• S (2 sec), if no change - to revert to Set A Lead-in.
Set Depth Alarm, information includes (Fig. 51):
> Graphics SEt and DPTH AL.
> Set Point graphic OFF (or Depth value) flashing with FT (or M) icon.
• A (hold) - to scroll upward through Set Points (8/sec)from OFF to 30 through 330 FT (10 through 100 M) in increments of
10 FT (1 M).
• A (< 2 sec) - to step upward through Set Points.
• M (< 2 sec) - to step back through Set Points.
• S (< 2 sec) - to save the setting and access Set EDT Alarm.
• S (2 sec), if no change - to revert to Set Audible.
Set EDT Alarm, information includes (Fig. 52):
> Graphics SEt and EDT AL.
> Set Point graphic OFF (or Time value) flashing with min icon.
• A (hold) - to scroll upward through Set Points (8/sec) from OFF to 10 through 180 (min) in increments of 5 min.
• A (< 2 sec) - to step upward through Set Points.
• M (< 2 sec) - to step back through Set Points.
• S (< 2 sec) - to save the setting and access Set TLBG Alarm.
• S (2 sec), if no change - to revert to Set Depth Alarm.
Set TLBG Alarm (NORM), information includes (Fig. 53):
> Graphics SEt and TLBG AL.
> Set Point graphic OFF (or TLBG segments) flashing.
• A (< 2 sec) - to step upward through Set Points from OFF to 1 through 4 segments.
• M (< 2 sec) - to step back through Set Points.
• S (< 2 sec) - to save the setting and access Set DTR Alarm.
• S (2 sec), if no change - to revert to Set EDT Alarm.
Set DTR Alarm (NORM), information includes (Fig. 54):
> Graphics SEt and DTR AL.
> Set Point graphic OFF (or Time value) flashing with min icon.
• A (hold) - to scroll upward through Set Points (8/sec) from OFF to 1 through 20 (min) in increments of 1 min.
• A (< 2 sec) - to step upward through Set Points.
• M (< 2 sec) - to step back through Set Points.
• S (< 2 sec) - to save the setting and access Set Turn Alarm.
• S (2 sec), if no change - to revert to Set TLBG Alarm.
Set Turn Alarm (TMT1 only), information includes (Fig. 55):
> Graphics SEt and TURN AL with Tank 1 icon.
> Set Point graphic OFF (or Pressure value) flashing, with PSI (or BAR) icon.
• A (hold) - to scroll upward through Set Points (8/sec) from OFF to 1000 to 3000 PSI (70 to 205 BAR) in 250 PSI (5 BAR)
increments.
• A (< 2 sec) - to step upward through Set Points.
• M (< 2 sec) - to step back through Set Points.
• S (< 2 sec) - to save the setting and access Set End Alarm.
• S (2 sec), if no change - to revert to Set DTR Alarm.
Fig. 49 - SET A LEAD-IN
Fig. 50 - SET AUD AL
Fig. 51 - SET DEPTH AL
Fig. 52 - SET EDT AL
Fig. 53 - SET TLBG AL
Fig. 54 - SET DTR AL
Fig. 55 - SET TURN AL
(applies to TMT 1 only)
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic Atom 3.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic Atom 3.0 in the language / languages: English as an attachment in your email.

The manual is 12,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic Atom 3.0

Oceanic Atom 3.0 Quick start guide - English - 2 pages

Oceanic Atom 3.0 User Manual - German - 56 pages

Oceanic Atom 3.0 Quick start guide - French - 2 pages

Oceanic Atom 3.0 User Manual - French - 56 pages

Oceanic Atom 3.0 Quick start guide - Italian - 2 pages

Oceanic Atom 3.0 User Manual - Italian - 56 pages

Oceanic Atom 3.0 User Manual - Spanish - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info