474197
11
Zoom out
Zoom in
Previous page
1/31
Next page
Deleting all the hand transmitters programmed
for the operator:
Plug in the operator's mains plug and whilst
button pressed.
Menu stage 3: Setting/adjusting the top
end of-travel position
Keep button pressed for 3 seconds.
Number 3 appears in the display.
Wait a short while until the 3 starts flashing.
Press button . The operator causes the door
to travel in the OPEN direction as long as the
button is pressed. The position can be altered
to the CLOSE direction via button .
Once the desired OPEN end-of-travel position
has been reached, press button . The
operator stores the OPEN end-of-travel
position and "4" appears in the display.
Menu stage 4: Setting/adjusting the
bottom end-of-travel position
Wait a short while until "4" starts flashing.
Press button . The operator causes the door
to travel in the CLOSE direction as long as the
button is pressed. The position can be altered
to the OPEN direction via button .
Once the desired CLOSE end-of-travel
position has been reached, press button .
The operator stores the CLOSE end-of-travel
position and "5" appears in the display.
Press button twice until "0" appears.
18a Force-learning cycle
Attention: During this opening and closing
cycle the operator learns the force required to
open and close the door. A force limit does not
apply! The cycles must not be interrupted.
During these cycles "0" appears in the display.
- Press button . The operator causes the
door to open until the top end-of-travel
position has been reached.
- Now press button again. The operator
causes the door to close until the bottom end-
of-travel position has been reached.
- After approx. 2 seconds "0" goes out.
Menu stage 5: The opening force limit
If you have previously quit the setting menu,
press button for 3 seconds until "3"
appears. Then press button twice until "5"
appears.
After approx. 2 seconds the display flashes
showing the set value of the opening force
limit.
The force limit setting can be increased or
decreased via buttons and .
After setting the value, press button .
The display shows "6".
Menu stage 6: The closing force limit
After approx. 2 seconds the display starts
flashing and the set value for the closing force
limit is displayed.
The force limit setting can be increased or
decreased via buttons and .
After setting the value, press button . "0"
appears in the display.
Finally, check the force settings and, if
necessary, repeat the setting procedure.
The maximum force at the main closing edge
must not exceed 150N!
Caution! If the force setting is too high,
persons may be placed at risk of injury.
The factory setting is 4!
Programming the Operator
Control elements
The controls for programming the door
operator are protected by a transparent cover.
The transparent cover can be opened with a
screwdriver.
After the operator has been programmed, the
transparent cover must be closed again.
A - Numerical display shows the menu stage
as well as the selected value.
a - Point display, lights up to indicate "ready
for operation" and flashes on the hand
transmitter code learning completion.
B - Button during the setting/adjustment
phase serves as an "up" button and
outside the menu as a start button.
C - Button during the setting/adjustment
phase serves as a "down" button.
D - Button is used to call up the
setting/adjustment menu, to change the
menu stages and to store the settings.
Programming the control unit is menu-driven.
Pressing button calls up the menu guide.
The numbers displayed indicate the menu
stage. After approx. 2 seconds the display
flashes and the setting can be altered via
buttons and .
The selected setting is stored with button
And the programme jumps automatically to the
next menu stage. By repeatedly pressing
button menu stages can be skipped. To
quit the menu, press button until "0" is
shown again. Outside the menu, button can
be used to generate a start impulse.
Before programming
- Allow door to engage into the carriage.
- Pull out the mains plug. Point display (a)
lights up.
- Make sure that the aerial is correctly
positioned (see figure 13).
- Observe the hand transmitter instructions.
Menu stage 1: Programming the start
function for the hand transmitter
Briefly press button .
"1" is displayed.
As soon as the display flashes, press and keep
pressed for approx. 1 second the button of the
hand transmitter, with which you later wish to
start the operator.
As soon as the code has been read, the red
point display (a) flashes five times before
quitting.
Further hand transmitters (up to a maximum of
10) can be programmed.
Menu stage 2 : Programming the light
function for the hand transmitter
Press button .
"2" appears in the display.
Note: If no 4-minute light is to be programmed,
repress button . The display shows "0" -
programming is completed.
Press the second button on the hand
transmitter, with which the 4-minute light is to
be switched on.
As soon as the code has been read, the red
point display (a) flashes five times before
quitting.
After the code has been learned, briefly press
button .
"0" appears indicating that you have come to
the end of the menu.
1414
1515
1616
1818
1717
2121
1919
2020
Checking the force limit facility
- Place an obstruction (e. g. operator's
cardboard box) underneath the door's
cosing edge.
- Starting from the OPEN end-of-travel
position, actuate the door to close.
- The door travels towards the obstruction,
stops and travels back to the top end-of-
travel position.
- The point display (a) must switch off for
approx. 1 second. Then the operator
functions as normal again.
If the door springs have been changed or
altered, then the force learning cycle must be
repeated:
Proceed to menu stage 5 and keep button
Pressed for 3 seconds. "0" appears in the
display. Then complete the force learning cycle
as explained under point 18a.
Special settings
Menu stage 7: Light phases
Press button for 3 seconds.
"3" appears in the display.
Press button several times until menu
stage 6 is shown.
Keep button pressed again for 3 seconds
until "7" appears in the display.
Menu Light phase Warning
value phase
If the warning phase is set, the light flashes
before the door starts to move and during the
actual travel cycle. The factory setting is 1.
Menu stage 8: "Soft" start and "soft" stop ("soft"
runs)
Press button . "8" appears in the display.
These values correspond to the "soft" runs
measured in cm at the carriage.
Important note:
The factory setting of 4 must be adhered to.
The "soft" runs may only be altered on the
express permission of the door manufacturer.
Press button . "0" appears in the display.
0 60 s -
1 90 s -
2 120 s -
3 240 s -
4 0 s 3 s
5 90 s 3 s
6 240 s 3 s
7 0 s 10 s
8 90 s 10 s
9 240 s 10 s
Menu Start Stop Start Stop
Value Open Open Close Close
0 0 0 0 0
1 15 0 15 0
2 0 15 0 60
3 15 15 15 35
4 25 45 25 45
5 15 15 15 60
6 15 15 15 15
7 35 35 35 50
8 60 15 15 85
9 soft run only
Retain these installation, operating and maintenance instructions for the full duration of the operator’s service life!
GB
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Novoferm Novomatic 403 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Novoferm Novomatic 403 in the language / languages: English, Dutch, French, Spanish as an attachment in your email.

The manual is 1,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Novoferm Novomatic 403

Novoferm Novomatic 403 User Manual - English, German, Dutch, French, Spanish - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info